–
41
–
9-2-6 Indoor Unit Fixing
1. Pass the pipe through the hole in the wall, and hook the indoor unit on
the installation plate at the upper hooks.
2. Swing the indoor unit to right and left to confirm that it is firmly hooked
up on the installation plate.
3. While pressing the indoor unit onto the wall, hook it at the lower part
on the installation plate. Pull the indoor unit toward you to confirm that
it is firmly hooked up on the installation plate.
Fig. 9-2-14
•
For detaching the indoor unit from the installation plate pull the indoor
unit toward you while pushing its bottom up at the specified parts.
Fig. 9-2-15
80
°
270 mm
170 mm
43 mm
50 mm
or more
Do not put the
drain hose end
into water.
Do not put the
drain hose end
in the drainage
ditch.
Do not form the drain hose into the
waved shape.
Do not rise the drain hose.
Extension drain hose
Inside the room
Drain hose
Shield pipe
Hook
1
Installation plate
Hook here
Press
(unhook)
Push
Wall
Drain
guide
Space for pipes
This air conditioner has the structure
designed to drain water collected from
dew, which forms on the back of the
indoor unit, to the drain pan.
Therefore, do not store the power cord
and other parts at a height above the
drain guide.
Push
CAUTION
•
Bind the auxiliary pipes (two) and connecting cable with facing tape
tightly. In case of leftward piping and rear-leftward piping, bind the
auxiliary pipes (two) only with facing tape.
Fig. 9-2-13
•
Carefully arrange pipes so that any pipe does not stick out of the
rear plate of the indoor unit.
•
Carefully connect the auxiliary pipes and connecting pipes to each
other and cut off the insulating tape wound on the connecting pipe
to avoid double-taping at the joint, moreover, seal the joint with the
vinyl tape, etc.
•
Since dewing results in a machine trouble, make sure to insulate
both the connecting pipes. (Use polyethylene foam as insulating
material.)
•
When bending a pipe, carefully do it not to crush it.
NOTE
If the pipe is bent incorrectly, the indoor unit may unstably be set on the
wall.
After passing the connecting pipe through the pipe hole, connect the
connecting pipe to the auxiliary pipes and wrap the facing tape around
them.
Installation plate
Auxiliary pipes
Indoor unit
Connecting cable
(To the forefront of flare)
Liquid side
Outward form of indoor unit
Use the handle of screwdriver, etc.
1
2
Slit
In case of right or left piping
•
After scribing slits of the front panel
with a knife or a making-off pin, cut
them with a pair of nippers or an
equivalent tool.
In case of bottom right or bottom left piping
•
After scribing slits of the front panel
with a knife or a making-off pin, cut
them with a pair of nippers or an
equivalent tool.
Left-hand connection with piping
Bend the connecting pipe so that it is laid within 43 mm above the wall
surface. If the connecting pipe is laid exceeding 43 mm above the wall
surface, the indoor unit may unstably be set on the wall. When bending
the connecting pipe, make sure to use a spring bender so as not to
crush the pipe.
Bend the connection pipe within a radius of 30 mm (Ø6.35) 40 mm
(Ø9.52).
To connect the pipe after installation of the unit (figure)
Slit
Gas side
R30 or less (Ø6.35) R40 or less (Ø9.52) (Use polisin
(polyethylene core or the like for bending pipe.)
Fig. 9-2-12
Fig. 9-2-10
Fig. 9-2-11
9-2-7 Drainage
1. Run the drain hose sloped downwards.
NOTE
•
Hole should be made at a slight downward slant on the outdoor side.
Fig. 9-2-16
2. Put water in the drain pan and make sure that the water is drained out
of doors.
3. When connecting extension drain hose, insulate the connecting part
of extension drain hose with shield pipe.
Fig. 9-2-17
CAUTION
Arrange the drain pipe for proper drainage from the unit.
Improper drainage can result in dew-dropping.
Fig. 9-2-18
Содержание RAS-3M23YACV-E
Страница 66: ... 66 10 8 2 P C Board Layout Top View Bottom View ...
Страница 80: ... 80 CN600 MCC 758 ...
Страница 81: ... 81 MCC 775 ...