background image

Preparing Filters

1. Open the air inlet grille and remove the air 

fi

lters.

2. 

Loading Batteries (when use wireless operation.)

1. Remove the slide cover.
2. Insert 2 new batteries (AAA type) 

following the (+) and (–) positions.

Clock Setup

1. Push 

 by tip of the pencil.

If timer indication is 

fl

ashing, go to the next step 2.

2. Press 

 or 

 : adjust the time.

3. Press 

 : Set the time.

Remote Control Reset

Push 

 by tip of the pencil or

1. Remove the batteries.

2. Press 

.

3. Insert the batteries.

1

2

3
4

6

5

(

%

&

"

7

!

9

<
=

8

#

)

$

/

-

+

~

,

:
;

.

INDOOR UNIT DISPLAY

1

PREPARATION BEFORE USE

2

AIR FLOW DIRECTION

Note:

  The provided Remote Controller is a wireless type, which also can be 

used as a wire. Please see “How to Connect The Remote Controller 
for Wired Operation”, located in installation instruction, in case of wired 
control is required.

  In wire operation, remote controller will return to initial condition 

(PRESET, TIMER and CLOCK will return to initial condition) when user 
shutdown power supply of Air conditioner.

REMOTE CONTROL

4  

AUTOMATIC OPERATION

6

To automatically select cooling, heating, or fan only operation

1. Press 

02'(

 : Select Auto A.

2. Press 

 : Set the desired temperature. Min. 17°C, Max. 30°C.

3. Press 

)$1

 : Select AUTO, LOW  , LOW+ 

, MED 

MED+ 

, HIGH 

 or Quiet 

1. Press 

02'(

 : Select Cool 

, Heat 

, or Fan only 

.

2. Press 

 : Set the desired temperature. Min. 17°C, Max. 30°C.

  Fan Only: No temperature indication

3. Press 

)$1

 : Select AUTO, LOW  , LOW+ 

, MED 

MED+ 

, HIGH 

 or Quiet 

COOLING / HEATING / FAN ONLY 
OPERATION

5

DRY OPERATION

7

For dehumidi

fi

cation, a moderate cooling performance is controlled 

automatically.

1. Press 

02'(

 : Select Dry 

.

2. Press 

 : Set the desired temperature. Min. 17°C, Max. 30°C.

Note: 

DRY mode fan speed is set to Auto only.

Hi POWER OPERATION

8

To automatically control room temperature and air

fl

ow for faster cooling or 

heating operation (except in DRY and FAN ONLY mode)

Press 

+L32:(5

: Start and stop the operation.

1

Press 

),;

 : Move the louver 

in the desired vertical direction.

2

Press 

FIX

 : Move the 

louver in the desired horizontal 
direction.

3

Press 

6:,1*

 : For select 

louver swing operation.

Vertical 

(Up-Down)

Swing

Horizontal 

(Left-Right) 

Swing

Swing off

Up-Down 

Left-Right 

Swing

Pi

Pi

Pi

Pi Pi

 

Vertical (Up-Down) swing

 

Horizontal (Left-Right) swing

Note:

  Do not move the louver manually by hands or others.

  The louver may automation positioning by some operation mode.

  Display brightness can be adjusted, follow procedure on  .

ͤ

 Require Wireless LAN connecting adapter which available as accessory.

1

ECO (White)

2

Wi-Fi access (White) 

ͤ

3

Hi Power (White)

4

Timer (White)

5

Operation Mode
- Cool (Blue)
- Heat (Orange)

1

Infrared signal emitter

2

Memory and Preset button (PRESET)

3

Start/Stop button

4

Mode select button (MODE)

5

Air 

fl

 ow button

6

Fireplace/8°C button

7

ECO button

8

Comfort sleep button (COMFORT SLEEP)

9

Weekly timer (ON/OFF)

!

Temp for Weekly timer

"

On timer button (ON)

#

Set clock button (CLOCK)

$

Check button (CHECK)

%

Filter reset button (FILTER)

&

Temperature button (TEMP)

(

Swing louver button (SWING)

)

Fan speed button (FAN)

~

Set louver Left-Right button (FIX 

W

)

+

Set louver Up-Down button (FIX 

X

)

,

High power button (Hi POWER)

-

Power selection/Silent button (P-SEL/SILENT)

.

Program P1 - P4

/

Day/Edit button

:

Setup button (SET)

;

Off timer button (OFF)

<

Clear button (CLR)

=

Reset button (RESET)

4

Press 

 to select provided air 

fl

 ow direction.

Wide 

center

Wide right

Spot left

Cancel Air 

Flow

Spot right

Spot 

center

Wide left

 

Pressing Indoor unit causes “Pi” sound (receiving tone) and 
“PiPi” sound when AIR FLOW is canceled.

%

Attach the filters. (see detail in the Installation Manual).

Содержание RAS-30E2AVG-A

Страница 1: ...OWNER S MANUAL R32 AIR CONDITIONER SPLIT TYPE For general public use 1126050202 Indoor unit RAS 30 34 36E2KVG A Outdoor unit RAS 30 34 36E2AVG A ...

Страница 2: ...losion or injury do not operate the unit when harmful gases e g flammable or corrosive are detected near the unit WARNING Do not expose your body directly to cool or warm air for a long time Do not insert your finger or any article into the air inlet outlet When an abnormality burning smell etc occurs stop the air conditioner and disconnect the power supply or turn off the breaker This appliance c...

Страница 3: ...e is pressurized Do not expose the appliance to heat flames sparks or other sources or ignition Else it may explode and cause injury or death CAUTION Do not wash the unit with water It may cause an electric shock Do not use this air conditioner for other purposes such as preserving food breeding animal etc Do not step or put anything on the indoor outdoor unit It may cause an injury or damage the ...

Страница 4: ... is set to Auto only Hi POWER OPERATION 8 To automatically control room temperature and airflow for faster cooling or heating operation except in DRY and FAN ONLY mode Press L 32 5 Start and stop the operation 1 Press Move the louver in the desired vertical direction 2 Press FIX Move the louver in the desired horizontal direction 3 Press 6 1 For select louver swing operation Vertical Up Down Swing...

Страница 5: ... the level is selected POWER SEL level flashes on remote LCD display for 3 seconds In case of 75 and 50 level number 75 or 50 also flashes for 2 seconds Due to the reason that POWER SELECTION function limits the maximum current inadequate cooling or heating capacity may occur Silent Operation Keep outdoor unit operating silently to ensure either yourself or neighborhood will have a tight sleep in ...

Страница 6: ...stop 4 Automatic defrosting Fans will stop during defrost operation 5 Heating capacity Heat is absorbed from outdoors and released into the room When the outdoor temperature is too low use another recommended heating apparatus in combination with the air conditioner 6 Consideration for accumulated snow Select the position for outdoor unit where it will not be subjected to snow drifts accumulation ...

Страница 7: ...n incomplete setting is indicated if the TIMER lamp is blinking Press twice Notes 1 Place the remote control where the indoor unit can receive the signal This will increase the accuracy of the timing between the remote control and the air conditioning unit 2 The ON OFF timer can be set during the WEEKLY TIMER operation In this situation the air conditioner will first follow the normal timer until ...

Страница 8: ......

Страница 9: ......

Страница 10: ......

Страница 11: ......

Страница 12: ...1126050202 ...

Отзывы: