Heating
/ 2
4
0V >
Total
A
B
C
Σ
kBTU
A
B
C
Heating capacity
(kW)
Power consumption
(W)
Operating current
(A)
1 unit
05
-
-
5
2.00
-
-
2.0
440
2.20
( 0.9
-
2.5 ) ( 190
-
580 ) ( 1.10
- 2.64 )
07
-
-
7
2.70
-
-
2.7
610
3.04
( 0.9
-
3.4 ) ( 190
-
820 ) ( 1.10
- 3.73 )
10
-
-
10
4.00
-
-
4.0
1050
5.15
( 0.9
-
4.8 ) ( 190
- 1380 ) ( 1.10
- 6.20 )
13
-
-
13
4.40
-
-
4.4
1350
6.55
( 1.0
-
5.2 ) ( 210
- 1410 ) ( 1.22
- 6.33 )
2 units
05
05
-
10
2.00
2.00
-
4.0
920
4.17
( 1.3
-
4.7 ) ( 250
- 1270 ) ( 1.45
- 5.65 )
07
05
-
12
2.70
2.00
-
4.4
960
4.35
( 1.3
-
4.8 ) ( 250
- 1270 ) ( 1.45
- 5.65 )
10
05
-
15
3.73
1.87
-
4.4
960
4.35
( 1.3
-
4.9 ) ( 250
- 1270 ) ( 1.45
- 5.65 )
13
05
-
18
4.00
1.60
-
4.4
950
4.30
( 1.3
-
5.0 ) ( 250
- 1250 ) ( 1.45
- 5.56 )
07
07
-
14
2.70
2.70
-
4.4
960
4.35
( 1.3
-
5.1 ) ( 250
- 1270 ) ( 1.45
- 5.65 )
10
07
-
17
3.34
2.26
-
4.4
950
4.30
( 1.3
-
5.1 ) ( 250
- 1250 ) ( 1.45
- 5.56 )
13
07
-
20
3.64
1.96
-
4.4
920
4.17
( 1.3
-
5.2 ) ( 250
- 1250 ) ( 1.45
- 5.56 )
10
10
-
20
2.80
2.80
-
4.4
930
4.21
( 1.3
-
5.1 ) ( 250
- 1230 ) ( 1.45
- 5.48 )
13
10
-
23
2.30
2.10
-
4.4
910
4.12
( 1.3
-
5.2 ) ( 250
- 1230 ) ( 1.45
- 5.48 )
13
13
-
26
2.20
2.20
-
4.4
890
4.05
( 1.3
-
5.2 ) ( 250
- 1220 ) ( 1.45
- 5.40 )
Operating
status
Indoor unit
Unit capacity (kW)
・
The above specification values are those under the conditions that the indoor DB/WB=20/-
℃
and the outdoor DB/WB=7/6
℃
.
FILE NO. SVM-18020