background image

5

Installation Manual

Outdoor Unit

 

WARNING

•  If you detect any damage, do not install the unit. Contact your supplying dealer immediately. 
•  Never modify this unit by removing any of the safety guards or bypassing any of the safety 

interlock switches. 

•  Do not wash air conditioners with pressure washers.

Electric leaks may cause electric shocks or fires. 

•  Be sure to comply with local regulations/codes when running the wire from the outdoor unit 

to the indoor unit. (Size of wire and wiring method etc.) 

•  When installing the air conditioner in a small room, provide appropriate measures to 

ensure that the concentration of refrigerant leakage occur in the room does not exceed the 
critical level. It is not dangerous refrigerant; it has not toxicity or combustibility. However, 
a concentration above 0.3 kg/m

3

 as criterion still causes suffocation. The volume of 

refrigerant charged to the Multi System air conditioner is more than the volume charged to a 
conventional individual system.

•  Make sure drain hose insulation if cooling operation is used at sub-zero ambient 

temperature.

 

CAUTION

•  Please read this installation manual carefully before installing the unit. It contains further 

important instructions for proper installation. 

•  Exposure of unit to water or other moisture before installation could result in electric 

shock. Do not store it in a wet basement or expose to rain or water. 

•  After unpacking the unit, examine it carefully for possible damage. 

•  Do not install in a place that can increase the vibration of the unit. Do not install in a place 

that can amplify the noise level of the unit or where noise and discharged air might disturb 

neighbours. 

•  This appliance must be connected to the main power supply by means of a circuit breaker 

depending on the place where the unit is installed. Failure to do so may cause electrical 

shock. 

•  Follow the instructions in this installation manual to arrange the drain pipe for proper 

drainage from the unit. Ensure that drained water is discharged. Improper drainage can 

result in water leakage, causing water damage to furniture. 

•  Tighten the flare nut with a torque wrench using the prescribed method. Do not apply 

excess torque. Otherwise, the nut may crack after a long period of usage and it may 

cause the leakage of refrigerant. 

•  Wear gloves (heavy gloves such as cotton gloves) for installation work. Failure to do so 

may cause personal injury when handling parts with sharp edges. 

•  Do not touch the air intake section or the aluminium fins of the outdoor unit. It may cause 

injury. 

•  Do not install the outdoor unit in a place which can be a nest for small animals. Small 

animals could enter and contact internal electrical parts, causing a failure or fire. 

•  Request the user to keep the place around the unit tidy and clean. 

•  Make sure to conduct a test run after the installation work, and explain how to use and 

maintain the unit to the customer in accordance with the manual. Ask the customer to 

keep the operation manual along with the installation manual.

•  Do not climb onto or place objects on top of the outdoor unit. You may fall or the objects 

may fall off of the outdoor unit and result in injury.

Requirement of report to the local power supplier 

Please make absolutely sure that the installation of this appliance is reported to the local 

power supplier before installation. If you experience any problems or if the installation is not 

accepted by the supplier, the service agency will take adequate countermeasures.

1116691099_(01) EN.indd   5

1116691099_(01) EN.indd   5

9/22/15   5:59 PM

9/22/15   5:59 PM

Содержание RAS-2M14S3AV-E

Страница 1: ... Manual Outdoor Unit Model name RAS 3M18S3AV E RAS 2M18S3AV E RAS 2M14S3AV E NOTE Descriptions about operations for the 3 indoor units in this manual are not applicable to RAS 2M18S3AV E and RAS 2M14S3AV E English Installation Manual Outdoor Unit ...

Страница 2: ...ng 10 9 Test run 10 10 Pump down Operation 12 11 Troubleshooting 12 Please read this Installation Manual carefully before installing the Air Conditioner This Manual describes the installation method of the outdoor unit For installation of the indoor unit refer to the Installation Manual attached to the indoor unit IMPORTANT NOTICE For details on how to install the indoor units refer to the install...

Страница 3: ...ity of severe injury 1 or death WARNING It indicates that incorrect use of this unit may cause severe injury or death CAUTION It indicates that incorrect use of this unit may cause personal injury 2 or property damage 3 1 A severe injury refers to blindness injury burns hot or cold electrical shock bone fracture or poisoning that leaves after effects and requires hospitalization or extended out pa...

Страница 4: ...oles must be incorporated in the fixed wiring Turn off main power supply before attempting any electrical work Make sure all power switches are off Failure to do so may cause electric shock Connect the connecting cables correctly If the connecting cables are connected wrongly electric parts may be damaged Check the earth wire that it is not broken or disconnected before installation Do not install...

Страница 5: ...s or the specified parts Failure to do so may cause the unit to fall water leakage fire or electrical shock After the installation work ensure that there is no leakage of refrigerant gas If the refrigerant gas leaks out of the pipe into the room and is heated by fire or something else from a fan heater stove or gas range it causes generation of poisonous gas Make sure the equipment is properly ear...

Страница 6: ... disturb neighbours This appliance must be connected to the main power supply by means of a circuit breaker depending on the place where the unit is installed Failure to do so may cause electrical shock Follow the instructions in this installation manual to arrange the drain pipe for proper drainage from the unit Ensure that drained water is discharged Improper drainage can result in water leakage...

Страница 7: ... combination of the indoor units which are operated The information in this specifications table applies for the combinations with the catalogue For operation read the owner s manual packed with the indoor unit Equipment complying with IEC 61000 3 12 1 If the air conditioner is used in conditions other than the above the safety protection functions may be activated Example of indoor unit class RAS...

Страница 8: ... to the wiring and piping lengths on the inside rather than the outside When using an air conditioner under low outside temperature conditions Outside temp 5 C or lower In COOL mode prepare a duct or wind shield so that it is not affected by the wind Necessary Space for Installation If you need to install the outdoor unit in a location where there are some obstructions or a wall secure sufficient ...

Страница 9: ...hexagon wrench 1 Connect a charge hose Make sure that the Handle Hi of the gauge manifold valve is closed fully Connect the port of the gauge manifold valve and the service port Valve core Setting Pin using the charge hose NOTE If a control valve or charge valve is attached to the charge hose leak of R410A refrigerant can be avoided 2 Open the Handle Low of the gauge manifold valve fully then oper...

Страница 10: ...r refrigerant leaks may be required depending on European or local legislation Insulation of the Refrigerant Pipes Insulate the refrigerant pipes for liquid and gas separately Heat proof bubble polyethylene Gas Leak Inspection Perform a gas leak inspection for the flare nut connections valve stem connection and service port cap without fail Use a leak detector exclusively manufactured for R410A Fl...

Страница 11: ...it Connect the connecting cable to the terminal as identified by the matching numbers on the terminal block of the indoor and the outdoor unit 5 Fix the wiring connections for the power source and each indoor unit securely using a cord clamp 6 Attach the terminal cover and the valve cover Stripping Length of connecting cable for outdoor unit 55 5 5 30 1 2 3 5 5 30 55 L N Earth wire Earth wire Powe...

Страница 12: ... or less Also there is a possibility to misjudge if the indoor temperature becomes too low by cooling operation In that case execute the cooling operation for per room and check if the connection is normal Gas Leak Inspection Refer to the Gas Leak Inspection on page 9 Test run 1 If you perform the test run in summer start running in the cooling mode first to decrease the temperature of the room th...

Страница 13: ...lve at the liquid end 9 Make sure that the compound pressure gauge reading is 101 kPa 76 cmHg 10 Close the valve stem of the service valve at the gas end 11 The refrigerants collection operation is finished in maximum 10 minutes After the collection is finished promptly stop the operation of all the indoor unit There are cases that the compressor restarts 12 When you want to start over the operati...

Страница 14: ...144 9 Moo 5 Bangkadi Industrial Park Tivanon Road Tambol Bangkadi Amphur Muang Pathumthani 12000 Thailand 1116691099 ...

Отзывы: