8
Drain hose
How to remove the drain hose
• The drain hose can be removed by removing the
screw securing the drain hose and then pulling out
the drain hose.
• When removing the drain hose, be careful of any
sharp edges of steel plate. The edges can injuries.
• To install the drain hose, insert the drain hose
firmly until the connection part contacts with heat
insulator, and then secure it with original screw.
How to remove the drain cap
Clip the drain cap by needle-nose
pliers and pull out.
How to fix the drain cap
1) Insert hexagon wrench (4 mm)
in a center head.
No gap
Insert a hexagon wrench
(4 mm).
Do not apply lubricating oil
(refrigerant machine oil)
when inserting the drain
cap. Application causes
deterioration and drain
leakage of the plug.
2) Firmly insert the drain cap.
CAUTION
Information
Firmly insert the drain hose and drain cap; otherwise, water may leak.
The lower part of indoor unit may float,
due to the condition of piping and you
cannot fix it to the installation plate. In
that case, use the
9
screws provided
to fix the unit and the installation plate.
Slit
Slit
In case of right or left piping
In case of bottom right or bottom left piping
• After scribing slits of the front panel
with a knife or a making-off pin, cut
them with a pair of nippers or an
equivalent tool.
• After scribing slits of the front panel
with a knife or a making-off pin, cut
them with a pair of nippers or an
equivalent tool.
Left-hand connection with piping
• Bend the connecting pipe so that it is laid within 43 mm above the wall
surface. If the connecting pipe is laid exceeding 43 mm above the wall
surface, the indoor unit may unstably be set on the wall.
When bending the connecting pipe, make sure to use a spring bender so
as not to crush the pipe.
Bend the connecting pipe within a radius of 30 mm.
To connect the pipe after installation of the unit (figure)
(To the forefront of flare)
Gas side
Liquid side
520 mm
43 mm
420 mm
Outward form of indoor unit
R 30 mm (Use polisin (polyethylene)
core or the like for bending pipe.)
Use the handle of screwdriver, etc.
If the pipe is bent incorrectly, the indoor unit may unstably be set on the wall.
After passing the connecting pipe through the pipe hole, connect the
connecting pipes to the auxiliary pipes and wrap the facing tape around
them.
NOTE
CAUTION
• Bind the auxiliary pipes (two) and connecting cable with facing tape
tightly. In case of leftward piping and rear-leftward piping, bind the
auxiliary pipes (two) only with facing tape.
• Carefully arrange pipes so that any pipe does not stick out of the rear
plate of the indoor unit.
• Carefully connect the auxiliary pipes and connecting pipes to one
another and cut off the insulating tape wound on the connecting pipe to
avoid double-taping at the joint; moreover, seal the joint with the vinyl
tape, etc.
• Since dewing results in a machine trouble, make sure to insulate both
connecting pipes. (Use polyethylene foam as insulating material.)
• When bending a pipe, carefully do it, not to crush it.
Indoor unit
Connecting cable
Auxiliary pipes
Installation plate
Indoor Unit Fixing
1. Pass the pipe through the hole in the wall and hook the indoor unit on the
installation plate at the upper hook.
2. Swing the indoor unit to right and left to confirm that it is firmly hooked up
on the installation plate.
3. While pressing the indoor unit onto the wall, hook it at the lower part on the
installation plate. Pull the indoor unit toward you to confirm that it is firmly
hooked up on the installation plate.
Hook here.
Hook
Press
(unhook)
Installation plate
1
• For detaching the indoor unit
from the installation plate,
pull the indoor unit toward
you while pushing its bottom
up at the specified parts.
Push
Push
9
Screw
9
Screw
1120650172-00_S01_182x257_36p_S_p70_181219.indd 8
6/2/2562 16:25:45