Gas Leak Test
Auto Restart Setting
The product was shipped with Auto Restart function in the off position.
Turn it on as required.
How to set the Auto Restart
Remote Control A-B Selection
To separate using of remote control for each indoor unit in case of 2 air
conditioners are installed near.
Remote Control B Setup.
1. Press [RESET] button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold [CHECK] button on the Remote Control by the tip of the
pencil. “00” will be shown on the display (Picture
1
).
4. Press [MODE] during pushing [CHECK]. “B” will show on the display
and “00” will disappear and the air conditioner will turn OFF. The Remote
Control B is memorized (Picture
2
).
Note : 1. Repeat above step to reset Remote Control to be A.
2. Remote Control A has not “A” display.
3. Default setting of Remote Control from factory is A.
• When two indoor units are installed in the same room or adjacent two
rooms, if operating a unit, two units may receive the remote control signal
simultaneously and operate. In this case, the operation can be preserved
by setting either one remote control to B setting. (Both are set to A setting
in factory shipment.)
• The remote control signal is not received when the settings of indoor unit
and remote control are different.
• There is no relation between A setting/B setting and A room/B room when
connecting the piping and cables.
This product is designed so that, after a power failure, it can restart
automatically in the same operating mode as before the power failure.
1. Press and hold the [RESET] button on the indoor unit for 3 seconds to
set the operation. (3 beep sound and OPERATION lamp blink 5 time/sec
for 5 seconds)
2. Press and hold the [RESET] button on the indoor unit for 3 seconds to
cancel the operation. (3 beep sound but OPERATION lamp does not
blink)
• In case of ON timer or OFF timer are set, AUTO RESTART
OPERATION does not activate.
Information
1
2
Test Operation
To switch to the TEST RUN (COOL) mode, press RESET button for
10 seconds. (The beeper will make a short beep.)
RESET button
• Check the
fl
are nut connections, valve stem cap connections and service
port cap connection for gas leak with a leak detection or soap water.
Flare nut connections
(Indoor unit)
Flare nut connections
(Outdoor unit)
Valve stem cap connection
Service port cap connection
01_1115551256-EN.indd 9
01_1115551256-EN.indd 9
8/26/2558 BE 2:50 PM
8/26/2558 BE 2:50 PM
Содержание RAS-24BAS-HK
Страница 21: ...MEMO 02_1115551256 CT indd 10 02_1115551256 CT indd 10 10 1 2558 BE 3 01 PM 10 1 2558 BE 3 01 PM ...
Страница 22: ...MEMO 02_1115551256 CT indd 11 02_1115551256 CT indd 11 10 1 2558 BE 3 01 PM 10 1 2558 BE 3 01 PM ...
Страница 23: ...02_1115551256 CT indd 12 02_1115551256 CT indd 12 10 1 2558 BE 3 01 PM 10 1 2558 BE 3 01 PM ...
Страница 24: ...1115551256 02_1115551256 CT indd 13 02_1115551256 CT indd 13 10 1 2558 BE 3 01 PM 10 1 2558 BE 3 01 PM ...