– 3
3
–
Item
3. Outdoor fan
motor control
Operation flow and applicable data, etc.
The blowing air volume at the outdoor unit side is controlled.
Receiving the operation command from the controller of
indoor unit, the controller of outdoor unit controls fan speed.
* For the fan motor, a DC motor with non-stage variable
speed system is used. However, it is limited to 8 stages for
reasons of controlling.
Description
1) The operation command sent
from the remote controller is
processed by the indoor unit
controller and transferred to the
controller of the outdoor unit.
2) When strong wind blows at
outdoor side, the operation of air
conditioner continues with the
fan motor stopped.
3) Whether the fan is locked or not
is detected, and the operation of
air conditioner stops and an
alarm is displayed if the fan is
locked.
4) According to each operation
mode, by the conditions of
outdoor temperature (To) and
compressor revolution, the speed
of the outdoor fan shown in the
table is selected.
Outdoor fan speed (rpm)
Tap
f 1
f 2
f 3
f 4
f 5
f 6
f 7
230
300
350
410
480
500
530
Tap
f 9
f A
f B
f C
f D
f E
f F
640
640
670
670
700
700
800
800
800
800
900
1000
900
1000
RAS-15EA Series
RAS-17EA Series
f 0
0
230
300
350
410
480
500
530
0
230
300
350
410
480
500
530
0
f 8
560
560
RAS-22EA Series
640
670
750
920
920
1000
1000
560
Tap
f 1
f 2
f 3
f 4
f 5
f 6
f 7
230
300
350
410
480
500
530
Tap
f 9
f A
f B
f C
f D
f E
f F
640
640
670
670
700
700
800
800
800
800
900
1000
900
1000
RAS-15LAV-UL
RAS-17LAV-UL
f 0
0
RAS-15LAV-UL
RAS-17LAV-UL
RAS-22LAV-UL
230
300
350
410
480
500
530
0
230
300
350
410
480
500
530
0
f 8
560
560
RAS-22LAV-UL
640
670
750
920
920
1000
1000
560
To
≥
100°F (38°C)
To
≥
82°F (28°C)
To
≥
59°F (15°C)
To
≥
42°F (5.5°C)
To
≥
32°F (0°C)
To
≥
22°F (-5°C)
To
≥
50°F (10°C)
To
≥
42°F (5.5°C)
To
≥
22°F (-5°C)
To <
22°F (-5°C)
To
≥
50°F (10°C)
To
≥
42°F (5.5°C)
To
≥
22°F (-5°C)
To
<
22°F (-5°C)
FILE NO. SVM-13070
In cooling operation
Compressor speed (rps)
To
During ECO,
QUIET and
comfort sleep
When To is abnormal
< 22.1
< 50.3
50.3 <
MIN MAX MIN MAX MIN MAX
f 6
f 9
f 8
f B
f A
f E
f 5
f 9
f 7
f B
f 9
f E
f 3
f 7
f 5
f 9
f 7
f B
f 1
f 3
f 1
f 7
f 3
f 9
f 1
f 3
f 1
f 5
f 3
f 7
f 0
f 1
f 0
f 3
f 1
f 4
f 6
f 9
f 8
f B
f A
f B
f 5
f 9
f 7
f B
f 9
f B
f 3
f 7
f 5
f 9
f 7
f B
f 1
f 3
f 1
f 7
f 3
f 9
f 1
f 3
f 1
f 5
f 3
f 7
f 0
f 1
f 0
f 3
f 1
f 4
f 1
f F
f 1
f F
f 1
f F
In Heating operation
Compressor speed (rps)
To
During
ECO mode
When To is abnormal
< 30.5
< 55.1
55.1 <
f 6
f 8
f 9
f 8
f A
f C
f A
f B
f D
f A
f B
f D
f 5
f 7
f 9
f 7
f 9
f B
f 9
f A
f B
f 9
f A
f B
f D
f D
f D
To
≥
100°F (38°C)
To
≥
82°F (28°C)
To
≥
59°F (15°C)
To
≥
42°F (5.5°C)
To
≥
32°F (0°C)
To
≥
22°F (-5°C)
Air conditioner ON
(Remote controller)
YES
YES
NO
NO
Indoor unit controller
Fan motor ON
3) Fan lock
4) Motor operates as shown in the table below.
1) Outdoor unit
operation
command
(Outdoor
fan
control)
Air conditioner
OFF
Alarm
display
2) Fan speed
≥
400.
(by strong wind)
when the motor OFF.
Fan motor OFF continues
(Use wind for heat
exchanging)
RAS-15EA Series
RAS-17EA Series
RAS-22EA Series