• These specifications are subject to change without notice for the purpose of incorporating technical improvements.
The specified air-conditioning performance is based on the data determined under the following conditions.
For details on the specifications when used in combination with a multi air conditioner outdoor unit, refer to the specifications table
provided with the multi air conditioner outdoor unit.
SPECIFICATIONS
Type
Reverse cycle, Split type
Model
Indoor Unit
Outdoor Unit
Indoor Unit
Outdoor Unit
RAS-B10SKVP-E
RAS-10SAVP-E
RAS-B13SKVP-E
RAS-13SAVP-E
Power supply
220–240 V ~50 Hz
220 V ~60 Hz
220–240 V ~50 Hz
220 V ~60 Hz
Cooling capacity
(kW) CAPA.
2.5
3.5
Heating capacity
(kW) CAPA.
3.2
4.2
Cooling current
(A)
AMP.
0.15
2.57–2.34
0.15
4.00–3.66
Cooling power
(W)
WATT.
30
460
30
820
Heating current
(A)
AMP.
0.15
3.15–2.87
0.15
4.40–4.02
Heating power
(W)
WATT.
30
600
30
920
Dimensions
Width (mm)
790
780
790
780
Height (mm)
250
550
250
550
Depth (mm)
208
290
208
290
Net weight
(kg)
9
38
9
38
Type
Reverse cycle, Split type
Model
Indoor Unit
Outdoor Unit
RAS-B16SKVP-E
RAS-16SAVP-E
Power supply
220–240 V ~50 Hz
220 V ~60 Hz
Cooling capacity
(kW) CAPA.
4.5
Heating capacity
(kW) CAPA.
5.5
Cooling current
(A)
AMP.
0.15
6.18–5.65
Cooling power
(W)
WATT.
30
1,320
Heating current
(A)
AMP.
0.15
6.83–6.25
Heating power
(W)
WATT.
30
1,460
Dimensions
Width (mm)
790
780
Height (mm)
250
550
Depth (mm)
208
290
Net weight
(kg)
9
38
For cooling
For heating (heat pump models)
Air inlet temperature °C
Indoor coil assembly
Outdoor coil assembly
Dry bulb
Wet bulb
Dry bulb
Wet bulb
27
19
35
24
Air inlet temperature °C
Indoor coil assembly
Outdoor coil assembly
Dry bulb
Wet bulb
Dry bulb
Wet bulb
20
—
7
6