– 55 –
FILE NO. SVM-12059
<How to install the air inlet grille on the indoor unit>
10-3-4. Piping and drain hose installation
<Piping and drain hose forming>
* Since dewing results in a machine trouble, make
sure to insulate both the connecting pipes. (Use
polyethylene foam as insulating material.)
2. Changing drain hose
For leftward connection, bottom leftward connection
and rear leftward connection’s piping, it is necessary to
change the drain hose and drain cap.
How to remove the drains cap
Clip drain cap by needle-nose plier, and pull out.
Fig. 10-3-11
CAUTION
Die-cutting Front panel slit
Changing drain hose
Piping preparation
Rear right
Rear left
Bottom left
Left
Bottom right
Right
How to install the drain hose
Firmly insert drain hose connecting part until hitting on
a heat insulator and fix it with a screw.
Fig. 10-3-12
Fig. 10-3-10
Control wire
Control wire
Hole for hang
remote controller
Remote controller
Screw (
∅
3.1 x 16L) for
hang remote controller
Wall
Screw (
∅
3.1 x 25L) for
fi x battery cover
Remote controller
"
#
Battery cover
Screw
$
Tighten fi rmly but
not over 0.15 N·m
(0.02 kgf·m)
1. Recommend to use double insulation lead wire for
connect remote control and air conditioner.
2. For wire operation, 1 remote control can control only
1 indoor unit.
3. In wire operation, remote controller will return to initial
condition (PRESET, TIMER and CLOCK will return to
initial condition) when user shutdown power supply
of air conditioner.
•
When attaching the air inlet grille, the contrary
of the removed operation is performed.
Cut out the slit on the left or right side of the front
panal for the left or right connection and the slit on the
bonttom left or right side of the front panel for the bottom
left or right connection with a pair of nippers.
1. Die-cutting front panel slit
•
The drain hose can be removed by removing the
screw securing the drain hose and then pulling out
the drain hose.
•
When removing the drain hose, be careful of any
sharp edges fo steel plate, The edges can injuries.
•
To install the drain hose, insert the drain hose firmly
until the connection part contacts with heat insulator,
and the secure it with original screw.
How to remove the drain hose
Heat insulator
Drain hose
* Remark :