FILE NO. SVM-12059
Item
Operation flow and applicable data, etc.
Description
PCB NO : MCC-5045
J201
1. Purpose
2. Description
3. Operation
Setting the remote controller
Remote Control B Setup.
1. Press [RESET] button on the indoor unit to turn the
air
conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold [CHECK] button on the Remote Control
by the tip of the pencil. "00" will be shown on
4. Press [MODE] during pushing [CHECK]. "B"
will show on the display and "00" will disappear
and the air conditioner will turn OFF. The Remote
NOTE : 1. Repeat above step to reset Remote
Control to be A.
2. Remote Control A has not "A" display.
3. Default setting of Remote Control from
Control B is memorized [Picture ).
factory is A.
the display (Picture ).
1
2
1
2
–
39
–
15.
Remote
Controller-A or
B selection
To separate using of remote controller for each indoor
unit in case of 2 air conditioner are installed nearly.
This operation is to operate only
one indoor unit using one remote
controller.
When operating one indoor unit in
a situation where two indoor units
have been installed in the same
room or nearby rooms, this
operation prevents the remote
controller signal from being
received simultaneously by both
units, thus preventing both units
from operating.
The indoor unit on which the
remote controller selection has
been set to B receives the signal of
the remote controller also set to B.
(At the factory the remote controller
selection is set to A on all the
indoor units.
There is no A setting display.)