– 4 –
RAS-13SK-E/13SA-E
RAS-13SKX/13SAX
COOLING
220V
230V
240V
3.70
3.70
3.75
Single
220/230/240
50
1.25/1.27/1.29
98/97/95
220V
220V
220V
0.15/5.66
0.15/5.56
0.15/5.53
24
2.0
44/39/36
47/48/48
R22
0.83
Capillary tube
12.7
Flare connection
6.35
Flare connection
15
6
16
RAS-13SK-E/RAS-13SKX
265
790
174
8
Finned tube
Cross flow fan
650
560
510
19
Polypropylene net filter (Washable)
RAS-13SA-E/RAS-13SAX
538
780
300
37
Finned tube
Propeller
1710/1800/1890
27
PH160T2-4L2
1100
Fuse, Overload relay
Yes
21 ~ 43
1. SPECIFICATIONS
Specifications are subject to change without notice.
↑
↓
Item
Capacity
Power source
Power consumption
Power factor
Running current
Starting current
Moisture removal
Noise
Refrigerant
Refrigerant control
Interconnection pipe
Condensate drain pipe
INDOOR UNIT
Dimensions
Net weight
Evaporator type
Indoor fan type
Air volume
Fan motor output
Air filter
OUTDOOR UNIT
Dimensions
Net weight
Condenser type
Outdoor fan type
Airflow volume
Fan motor output
Compressor
Safety device
Auto louver
Usable outdoor temperature range
*1
Indoor (H/M/L)
Outdoor (220/230/240V)
Name of refrigerant
Rated volume
Gas side size
Connection type
Liquid side size
Connection type
Maximum length (of one way)
Maximum height difference
Indoor unit
Outdoor unit
Outer diameter
Height
Width
Depth
High fan
Medium fan
Low fan
Height
Width
Depth
(220/230/240V)
Model
Output
Model
kW
Phase
V
Hz
kW
%
A
Indoor/Outdoor
A
lit/h
dB
dB
kg
mm
mm
m *2
m
mm
mm
mm
mm
kg
m
3
/h
m
3
/h
m
3
/h
W
mm
mm
mm
kg
m
3
/h
W
W
°C