– 15 –
7-5. AUTO Operation
(MODE of the remote control : AUTO)
(1) One of the 3 modes, Cooling, Fan only and Heat-
ing is selected according to room temperature at
which operation is to start, as shown in Fig. 7-5-1.
The Fan mode will continue until room tempera-
ture reaches a level at which another mode is se-
lected.
7-5-1. Temporary Auto
When the TEMPORARY button is pushed, the set
temperature is fixed at 24°C and controlled in accor-
dance with the chart shown in Fig. 7-5-1.
Fig. 7-5-1
Cooling mode
Cooling mode
Fan only mode
Heating mode
+4
+1
–1
(The same cooling mode as the room temperature control is set at set temp. –1˚C)
The Louver moved downward.
(The same cooling mode as the room temperature control is set at set temp. –1˚C)
(Only the indoor fan operates at Low speed)
(The same heating mode as the room temperature control is set at set temp. +1˚C)
(Room temp. – Set temp.)