  ONE-TOUCH

Press the “ONE-TOUCH” button for fully automated operation that is customized 

to the typical consumer preferences in your region of the world. The customized 

settings control temperature air fl ow strength, air fl ow direction and other settings 

to provide you alternate contact with “ONE-TOUCH” of the button. If you prefer 

other settings you can select from the many other operating functions of your 

Toshiba unit.

Press

ONE-TOUCH

 : Start the operation.

2

  PREPARATION BEFORE USE

Preparing Filters

1.  Open the air inlet grille and remove the air fi lters.

2.  Attach the attachment fi lters (see detail in the 

accessory sheet).

Loading Batteries

1. Remove the battery cover.

2. Insert 2 new batteries (AAA type) following the 

(+) and (–) positions.

Removing the batteries

1. Remove the cover, and take out the batteries.

2. Reattach the cover.

  •  Please dispose of the batteries according 

  to the local regulation.

Clock Setup

1. Push CLOCK • by tip of the pencil.

  If timer indication is fl ashing, go to 

the next step 2.

2. Press 

ON

 or 

OFF

: adjust the 

time.

3. Press 

: Set the time.

Remote Control Reset

1. Remove the batteries.

2. Press 

3. Insert the batteries.

Note:

•  Do not move the vertical louver manually by others.

•  The vertical louver may automation positioning by some operation mode.

•  On heating operation, in case of AIR OUTLET SELECT is set as Lower, 

upper louver is not operate even if swing is set by remote, though receiving 

history is recorded.

•  When changed the air fl ow to up/down or upward blowing, the swing 

operation will be performed.

•  At the time of FLOOR WARMING OPERATION, the air will blow downward 

only and it cannot order to swing operation with remote control.

3

  AIR FLOW DIRECTION

1

Press

 : Move the louver 

in the desired vertical direction.

2

Press

: Swing the air 

automatically and press again 

to stop.

3

For horizontal direction, adjust 

manually.

4

  REMOTE CONTROL

1

   Infrared signal emitter

2

   Start/Stop button

3

   Mode select button (MODE)

4

   Temperature button (TEMP)

5

   Fan speed button (FAN)

6

   Swing louver button (SWING)

7

   Set louver button (FIX)

8

   On timer button (ON)

9

   Off timer button (OFF)

!

   Sleep timer button (SLEEP)

"

   Setup button (SET)

#

   Clear button (CLR)

$

   Memory and Preset button (PRESET)

%

   One-Touch button (ONE-TOUCH)

&

   High power button (Hi-POWER)

(

   Economy button (ECO)

)

   Quiet button (QUIET)

~

   Comfort sleep button (COMFORT SLEEP)

+

   Filter reset button (FILTER)

,

   Clock Reset button (CLOCK)

-

   Check button (CHK)

.

   Floor warming mode button (FLOOR)

1

   OPERATION button : Unit operation ON/OFF button, turn off FILTER CHECK 

  Indicator.

2

   MODE button : Operation mode (Auto

 

Cooling

 

Heating

 

Auto

 

•  •  • 

)

※  

CHILD LOCK function : Press MODE button for 3 seconds. (It is possible to 

  operate even when stopping.)

    To cancel CHILD LOCK function, press MODE button for 3 seconds once  

  again. 

    When CHILD LOCK function is activated, 3 beeps will sound. 

    When press MODE button to cancel the function, a beep will sound and then  

  3 seconds later 3 beep sound may occur. 

    The indicator button will be invalid while the child lock function is activated.

    (When press the button, 1 beep will sound).

    Operation with remote control during the CHILD LOCK function works. 

    This function is cancelled when the power supply is off or failure. 

3

   AIR OUTLET SELECT button : Cooling, Auto (Upper & Lower

 

Upper

 

Upper & Lower

 

•  •  •

)

    Dry (upper only)

    Heating (Upper & Lower

 

Upper

 

Lower

 

Upper & Lower

 

•  •  •

)

    On cooling operation, whichever air outlet is set, only Upper is used when the  

  room temperature approaches the set temperature.

    During stop operation : Open/close the lower air outlet grille.

    When the TEMPERATURE indicator display “CL” the lower air outlet grille

  will be in closed status.

    When the TEMPERATURE indicator display “OP” the lower air outlet grille 

  will be in open status.

4

   TEMPERATURE button (Up) : Setting temperature increase by 1°C (17°C

 

18°C

 

•  •  • 

30°C)

5

   TEMPERATION button (Down) : Setting temperature decrease by 1°C    

  (30°C

 

29°C

 

•  •  • 

17°C)

6

   COOL and DRY indicator (Blue)

7

   HEAT indicator (Orange)

8

   AUTO indicator (Green)

9

   OPERATION indicator (Green)

!

   HI-POWER indicator (Green)

"

   FLOOR indicator (Orange)

#

   TIMER indicator (Yellow)

$

   FILTER CHECK indicator (Red)

%

   TEMPERATURE indicator (Blue)

&

   AIR OUTLET indicator (Green)

1

  INDOOR UNIT DISPLAY & UNIT OPERATION    

  PANEL

This indoor unit can be operated with the unit operation panel or using remote 

control.

Operational contents will be followed the one which was operated later.

If change the set temperature with operation panel of unit, temperature indication 

will be changed, but the temperature display on the remote control will not change.

If set the air fl ow only with the upper port, a little air fl ow may happen at the lower 

port.

Remote control 

light receiver

6

  AUTOMATIC / COOLING (DRY) / HEATING  

 

  OPERATION

1.  Press 

: Select A. Cool  , Dry  , Heat  .

2.  Press 

TEMP

: Set the desired temperature.

  Min. 17°C, Max. 30°C.
3.  Press 

 : Select AUTO, LOW  , LOW+  , MED 

, MED+ 

, or 

HIGH

.

※ 

AUTOMATIC OPERATION : Choose cooling or heating operation automatically. 

※ 

In DRY OPERATION mode, it can not select air volume.

Upper air outlet grille

Main operation part

Air inlet grille

Lower air 

outlet grille

Содержание RAS-10 series

Страница 1: ...UOMI NORSK DANSK ROMÂNĂ БЪЛГАРСКИ EESTI LATVISKI SLOVENČINA SLOVENŠČINA 1112150101 COVER_F OWNER S MANUAL AIR CONDITIONER SPLIT TYPE For general public use Indoor unit RAS B 10 13 18UFV Series Outdoor unit RAS 10 13 18SAV Series RAS M14GAV E RAS M18GAV E RAS 3M18SAV E RAS 3M26GAV E1 RAS 4M23SAV E RAS 4M27GAV E1 RAS 5M34UAV E ...

Страница 2: ...button QUIET Comfort sleep button COMFORT SLEEP Filter reset button FILTER Clock Reset button CLOCK Check button CHK Floor warming mode button FLOOR 1 OPERATION button Unit operation ON OFF button turn off FILTER CHECK Indicator 2 MODE button Operation mode Auto Cooling Heating Auto CHILD LOCK function Press MODE button for 3 seconds It is possible to operate even when stopping To cancel CHILD LOC...

Страница 3: ...leaning operation is started automatically and the TIMER indicator on the unit s display panel turns on Cleaning operation duration The cleaning operation lasts for 30 minutes if the unit has been operating in the cooling or dry mode for 10 minutes or more Note SELF CLEANING operation is default setting from factory How to cancel SELF CLEANING operation Press and hold MODE button on operation pane...

Страница 4: ... 2 Darkness Darkness 3 Turn off Darkness 4 Turn off Turn off Note When there is an abnormality in the product abnormal code 2 digits will be displayed on the unit display panel Please contact the dealership In case of multiple connection Check whether the operation mode is different from what has been selected for the units in the other rooms The following combinations of operations cannot be perf...

Страница 5: ...ítko režimu zahřívání podlahy FLOOR 12 13 11 Tlačítko OPERATION Provoz Tlačítko provozu jednotky ON OFF Zap vyp vypnutí indikátoru FILTER CHECK Kontrola filtru Tlačítko MODE Režim Provozní režim Automaticky Chlazení Topení Automaticky Funkce CHILD LOCK Ochrana před dětmi Stiskněte tlačítko MODE Režim a držte jej po dobu 3 sekund Lze provést i při zastavování Chcete li funkci CHILD LOCK Ochrana před...

Страница 6: ...ní jednotky Jestliže se jednotka vypne poté co byla v chodu 10 nebo více minut v chladicím nebo suchém režimu automaticky se spustí čištění a rozsvítí se indikátor TIMER na zobrazovacím panelu jednotky Trvání čisticího provozu Čisticí provoz trvá 30 minut pokud byla jednotka v provozu v chladicím nebo vysoušecím režimu 10 minut nebo déle Poznámka SAMOČISTĚNÍ je základní nastavení z výroby Zrušení ...

Страница 7: ...se na 5 sekund rozsvítí na indikátoru TEMPERATURE Teplota nápis 1 Chcete li se vrátit k předchozímu nastavení stiskněte a podržte znovu tlačítko AIR OUTLET SELECT Výběr vzduchového výstupu na dobu delší než 10 sekund tentokrát se ozvou 4 pípnutí a na indikátoru TEMPERATURE Teplota se po dobu 5 sekund rozbliká nápis 0 23 ÚDRŽBA MŘÍŽKY VSTUPU VZDUCHU Mřížku vstupu vzduchu omyjte jemnou houbičkou či ...

Страница 8: ...ERATION Tipka za stavljanje jedinice u ON OFF položaj isključite okazivač FILTER CHECK provjera filtra Tipka MODE Način rada Auto Cooling Heating Auto automatski rad hlađenje grijanje automatski rad Funkcija CHILD LOCK blokada za djecu Držite pritisnutom tipku MODE način rada 3 sekunde Moguće je upravljati jedinicom čak i prilikom zaustavljanja rada Za otkazivanje funkcije CHILD LOCK blokada za dje...

Страница 9: ...ama 17 SAMOČIŠĆENJA SAMO KOD HLA ENJA I SUHOG RADA Čišćenje Ta se funkcija koristi za unutarnje sušenje klimatizacijskog uređaja radi smanjenja razvoja plijesni itd u njemu Kada se jedinica isključi nakon najmanje 10 minuta hlađenja ili sušenja automatski se pokreće operacija čišćenja i uključuje se indikator TIMER na zaslonu jedinice Trajanje čišćenja Ako je jedinica hladila ili sušila najmanje 1...

Страница 10: ...e 1 Uobičajeno Uobičajeno 2 Tamno Tamno 3 Isključeno Tamno 4 Isključeno Isključeno Napomena Ako dođe do nepravilnog rada proizvoda šifra nepravilnosti 2 brojke pojavit će se na zaslonu poslužne ploče jedinice Molimo obratite se prodavaču U slučaju višestrukih spojeva Provjerite razlikuje li se način rada od odabranih načina rada za jedinice u ostalim prostorijama Ne mogu se vršiti sljedeće kombina...

Страница 11: ...R Takarékos üzemmód gomb ECO Csendes üzemmód gomb QUIET Kényelmi automatikus kikapcsolás gomb COMFORT SLEEP Szűrő helyreállítás gomb FILTER Óra beállítás gomb CLOCK Ellenőrzés gomb CHK A padlófűtés üzemmód gombja FLOOR 1 ÜZEMELTETÉS gomb Az egység működtetését vezérlő BE KI gomb a SZŰRŐELLENŐRZÉS jelzés kikapcsolója 2 ÜZEMMÓDVÁLASZTÓ gomb Működtetési mód Automatikus Hűtés Fűtés Automatikus GYEREKZ...

Страница 12: ...lsejének kiszárítására szolgál a penész és egyebek növekedésének megakadályozására a légkondicionálón belül Ha az egység hűtés vagy szárítás üzemmódban 10 percig vagy tovább működött automatikusan elindul a tisztítási művelet és az egység kijelzőpanelén bekapcsol az TIMER jelzőlámpa A tisztítási művelet időtartama A tisztítási művelet 30 percet tart ha az egység 10 percet vagy többet működött hűté...

Страница 13: ...mpa 1 Szokásos Szokásos 2 Sötét Sötét 3 Kikapcsolva Sötét 4 Kikapcsolva Kikapcsolva Megjegyzés A termék rendellenes működése esetén egy kétjegyű hibakód jelenik meg az egység kijelzőjén Lépjen kapcsolatba a kereskedővel Több készülék csatlakoztatása esetén Ellenőrizze hogy az üzemeltetési mód eltér e attól ami a többi helyiség egységeihez lett választva A következő üzemmód kombinációk nem érhetők ...

Страница 14: ...ON chod Zapnutie vypnutie zariadenia zhasnutie kontrolky FILTER CHECK kontrola filtra 2 Tlačidlo MODE režim Voľba prevádzkového režimu Automatický Ochladzovanie Kúrenie Automatický Funkcia CHILD LOCK detská poistka Podržte tlačidlo MODE režim stlačené 3 sekundy Túto funkciu je možné aktivovať aj po zastavení činnosti Ak chcete zrušiť funkciu CHILD LOCK znova stlačte tlačidlo MODE na 3 sekundy Po ak...

Страница 15: ...o zariadenia Ked sa jednotka vypne po 10 alebo viac minútach prevádzky v režime chladenia alebo sušenia čistiaca prevádzka sa spustí automaticky a indikátor TIMER na displeji jednotky sa rozsvieti Doba trvania čistiacej prevádzky Čistiaca prevádzka trvá 30 alebo ak jednotka pracovala v chladiacom alebo vysušovacom režime 10 alebo viac minút Poznámka SAMOČISTENIE je základné nastavenie z výroby Ako...

Страница 16: ... Poznámka Keď v zariadení nastane abnormálny stav na zobrazovacom paneli zariadenia sa zobrazí kód abnormálneho stavu 2 miestny Kontaktujte predajcu V prípade viacnásobného zapojenia Skontrolujte či sa prevádzkový režim líši od režimu zvoleného v iných miestnostiach Zariadenie nemôže pracovať pri týchto kombináciách režimov COOL ochladzovanie a HEAT kúrenie DRY vysušovanie a HEAT kúrenie Zvoľte ro...

Страница 17: ... filtra FILTER Tipka za ponastavitev ure CLOCK Gumb za preveritev CHK Gumb načina za segrevanje tal FLOOR 1 Gumb OPERATION gumb za VKLOP IZKLOP enote izklop indikatorja za PREVERJANJE FILTRA 2 Gumb MODE obratovalni način Samodejno Hlajenje Gretje Samodejno Funkcija CHILD LOCK VAROVALO ZA OTROKE za 3 sekunde pritisnite gumb MODE Funkcija deluje tudi ko je enota izključena Če želite izključiti VAROVA...

Страница 18: ...enje notranjosti klimatske naprave s čemer se zmanjša rast plesni itd v notranjosti naprave Ko enoto zaustavite po 10 minutnem ali daljšem obratovanju v načinu hlajenja ali sušenja se bo funkcija čiščenja zagnala samodejno na prikazu enote pa se bo vklopil indikator ČASOVNIKA Trajanje čiščenja Čiščenje traja 30 minut če je enota delovala v načinu hlajenja ali sušenja 10 minut ali dlje Opomba Funkc...

Страница 19: ...a Temna 3 Izključi Temna 4 Izključi Izključi Opomba Pri napaki z izdelkom se na upravljalni plošči prikaže koda napake 2 številki Stopite v stik s prodajalcem Pri več priključkih Preverite ali se obratovalni način razlikuje od načina izbranega za enote v drugih prostorih Možne so naslednje kombinacije postopkov HLAJENJE in OGREVANJE SUŠENJE in OGREVANJE Izberite enak način delovanja kot v drugih p...

Отзывы: