5
−
MODEL
RAS-07UKP-ES
4
RAS-07UA-ES
4
ITEM
Cooling
Capacity
220V
240V
kW 2.
23
2.
27
Phase
1
∅
Power source
V
220
−
240
Hz
50
Power consumption kW
0.68
0.
70
Power factor % 9
8
9
6
Running
Indoor
A
0.15
current Outdoor A 3.
0
0
2
.
90
Starting current A 1
3
Moisture removal
lit/h
0.8
Noise
Indoor (H/M/L)
dB
38/32/26
Outdoor (220-240V) dB
44
45
Refrigerant
Name of refrigerant
R410A
Rated amount kg 0.6
3
Refrigerant control
Capillary tube
Gas side size
mm
∅
9.52
Connection type
Flare connection
Liquid side size
mm
∅
6.35
Interconnection Connection type
Flare connection
pipe
Maximum length
m
10*
1
(One way)
Maximum height
difference
INDOOR UNIT RAS-07UKP-ES
4
Height
mm
275
Dimensions
Width
mm
790
Depth
mm
208
Net weight
kg
10
Evaporator type
Finned tube
Indoor fan type
Cross flow fan
High fan
m
3
/h
570
Air volume
Medium fan
m
3
/h
460
Low fan
m
3
/h
340
Fan motor output
W
20
Air filter
Honeycomb woven filter with PP frame
OUTDOOR UNIT RAS-07UA-ES
4
Height
mm
530
Dimensions
Width
mm
660
Depth
mm
240
Net weight
kg
27
Condenser type
Finned tube
Outdoor fan type
Propeller fan
Airflow volume m
3
/h
1420
1520
Fan motor output
W
30
Compressor
Model
PA82X1C-4DZDN
Output
W
605
Safety device
Fuse, Overload relay
Louver type
Automatic louver
Usable outdoor temperature range
°C
15 ~ 43
m
5
m
FILE NO. SVM-05020