– 3 –
FILE NO. SVM-06051
1. SPECIFICATIONS
Specification are subject to change without notice.
Note : Capacity is based on the following temperature conditions. (*)
MODE
SSA 385/386
JIS
ITEM
COOLING
COOLING
Indoor unit inlet air temperature
(DB)
29
°
C
27
°
C
(WB)
19
°
C
19.5
°
C
Outdoor unit inlet air temperature
(DB)
46
°
C
35
°
C
(WB)
24
°
C
24
°
C
MODEL RAC-24GE2B RAC-24G2B RAC-24G-AR RAC-24G2L
ITEM
COOLING (SSA)
HEATING
COOLING (SSA) COOLING (JIS)
COOLING (JIS)
Capacity*
k cal/h
4,800
3,440
4,800
—
—
Btu/h
5,600 (W)
4,000 (W)
5,600 (W)
6,500 (W)
6,500 (W)
Phase
Single
Single
Single
Single
Power source
V
220
220
220 – 240
220
Hz
60
60
50
60
Power consumption
W
3,750
4,400
3,750
3,100
3,200
Power factor
%
97
100
97
93
96
Running current
A
17.5
20.0
17.5
14.5
15.1
Starting current A 65 65 58 65
Moisture removal
lit/h
3.7
3.7
3.7
3.7
Noise
Indoor (Hi/Low) dB 58/53 58/53 58/53,60/55 58/53
Outdoor (Hi/Low) dB 64/59 64/59 64/59,66/62 64/59
Compressor output
W
2,000
2,000
2,200
2,000
Fan motor output
W
200
200
200
200
Refrigerant
Name of refrigerant
R22
R22
R22
R22
Charge volume kg 0.90 0.90 1.05 0.90
High Fan
m
3
/h
1,050
1,050
1,050
1,050
Air volume
Medium Fan
m
3
/h
—
—
—
—
Low Fan
m
3
/h
850
850
850
850
Refrigerant control
Capillary tube
Safety device
Over current relay for protection of compressor motor and fan motor
Control device
Selector switch, Thermostat, Auto louver switch
Ventilation
Yes
Auto louver
Yes
Height
mm
435
Dimensions
Width
mm
660
Depth mm 748
Net weight
kg
72
70
70
70
Usable outdoor temperature range
°
C
MAX. 52
Содержание RAC-24G-AR
Страница 9: ... 9 FILE NO SVM 06051 6 PERFORMANCE CHARACTER 6 1 RAC 24G AR ...
Страница 10: ... 10 FILE NO SVM 06051 6 2 RAC 24G2B 24GE2B ...
Страница 11: ... 11 FILE NO SVM 06051 6 3 RAC 24G2L ...