2.6 2.5” HDD Troubleshooting
2 Troubleshooting Procedures
QOSMIO F20 Maintenance Manual (960-526)
[CONFIDENTIAL]
2-41
Procedure 2
Message Check
When the power is turned on, the system performs the Initial Reliability Test (IRT) installed
in the BIOS ROM. When the test detects an error, an error message is displayed on the screen.
Turn on the computer and check the message on the screen. When an OS starts from the 2.5”
HDD, go to Procedure 3. Otherwise, start with Check 1 below and perform the other checks as
instructed.
Check 1
If any of the following messages appear, go to Procedure 3. If the following
messages do not appear, perform Check 2.
HDC ERROR
or
HDD #X ERROR
(After 5 seconds this message will disappear.)
Check 2
If either of the following messages appears, go to Check 3. If the following
messages do not appear, perform Check 4.
Insert system disk in drive
Press any key when ready .....
or
Non-System disk or disk error
Replace and press any key when ready
Check 3
Using the SYS command of the MS-DOS, transfer the system to the 2.5” HDD. If
the system is not transferred, go to Procedure 3. Refer to the MS-DOS Manual for
detailed operation.
If the following message appears on the display, the system program has been
transferred to the HDD.
System Transferred
If an error message still appears on the display, perform Check 4.
Check 4
The 2.5” HDD and the connector of the system board may be disconnected. Insert
the connectors firmly. (Refer to the steps described in Chapter 4,
Replacement
Procedures
for disassembling.) If they are firmly connected, go to Procedure 3.
Содержание QOSMIO F20 Series
Страница 10: ...x CONFIDENTIAL QOSMIO F20 Maintenance Manual 960 526 ...
Страница 11: ... CONFIDENTIAL Chapter 1 Hardware Overview ...
Страница 12: ...1 Hardware Overview 1 ii CONFIDENTIAL QOSMIO F20 Maintenance Manual 960 526 1 Hardware Overview ...
Страница 47: ... CONFIDENTIAL Chapter 2 Troubleshooting Procedures ...
Страница 48: ...2 Troubleshooting Procedures 2 ii CONFIDENTIAL QOSMIO F20 Maintenance Manual 960 526 2 ...
Страница 52: ...2 Troubleshooting Procedures 2 vi CONFIDENTIAL QOSMIO F20 Maintenance Manual 960 526 ...
Страница 111: ... CONFIDENTIAL Chapter 3 Tests and Diagnostics ...
Страница 112: ...3 Tests and Diagnostics 3 ii CONFIDENTIAL QOSMIO F20 Maintenance Manual 960 526 ...
Страница 117: ...3 Tests and Diagnostics QOSMIO F20 Maintenance Manual 960 526 CONFIDENTIAL 3 vii ...
Страница 227: ...3 31 SETUP 3 Tests and Diagnostics QOSMIO F20 Maintenance Manual 960 526 CONFIDENTIAL 3 105 ...
Страница 228: ... CONFIDENTIAL Chapter 4 Replacement Procedures ...
Страница 229: ...4 Replacement Procedures 4 ii CONFIDENTIAL QOSMIO F20 Maintenance Manual 960 526 4 ...
Страница 316: ... CONFIDENTIAL Appendices ...
Страница 317: ...Appendices App ii CONFIDENTIAL QOSMIO F20 Maintenance Manual 960 526 ...
Страница 322: ...Appendices QOSMIO F20 Maintenance Manual 960 526 CONFIDENTIAL App vii Table I 1 MTBF I 1 ...
Страница 323: ...Appendices App viii CONFIDENTIAL QOSMIO F20 Maintenance Manual 960 526 ...
Страница 329: ...Appendices Appendix A Handling the LCD Module A 6 CONFIDENTIAL QOSMIO F20 Maintenance Manual 960 526 ...
Страница 337: ...Appendices Appendix B Board Layout B 8 CONFIDENTIAL QOSMIO F20 Maintenance Manual 960 526 ...
Страница 373: ...Appendices Appendix C Pin Assignments C 36 CONFIDENTIAL QOSMIO F20 Maintenance Manual 960 526 ...
Страница 383: ...Appendices Appendix E Key Layout E 2 CONFIDENTIAL QOSMIO F20 Maintenance Manual 960 526 ...
Страница 385: ...Appendices Appendix F Wiring diagrams F 2 CONFIDENTIAL QOSMIO F20 Maintenance Manual 960 526 ...
Страница 387: ...Appendices Appendix G BIOS Rewrite Procedures G 2 CONFIDENTIAL QOSMIO F20 Maintenance Manual 960 526 ...
Страница 389: ...Appendices Appendix H EC KBC Rewrite Procedures H 2 CONFIDENTIAL QOSMIO F20 Maintenance Manual 960 526 ...
Страница 391: ...Appendices Appendix I Reliability I 2 CONFIDENTIAL QOSMIO F20 Maintenance Manual 960 526 ...