Troubleshooting Procedures
PORTEGE Z830 Satellite Z830 Series Maintenance Manual (960-883) [CONFIDENTIAL]
2-37
2.6.2 Procedure 2 Message Check
When the power is turned on, the system performs the Initial Reliability Test (IRT) installed
in the BIOS ROM. When the test detects an error, an error message is displayed on the screen.
Make sure no floppy disk is in the FDD. Turn on the computer and check the message on the
screen. When an OS starts from the 2.5” HDD, go to Procedure 3. Otherwise, start with Check
1 below and perform the other checks as instructed.
Check 1
If any of the following messages appear, go to Procedure 3. If the following
messages do not appear, perform Check 2.
HDC ERROR
or
HDD #X ERROR
(After 5 seconds this message will disappear.)
Check 2
If either of the following messages appears, go to Check 3. If the following
messages do not appear, perform Check 4.
Insert system disk in drive
Press any key when ready .....
or
Non-System disk or disk error
Replace and press any key when ready
Check 3
Using the SYS command of the DOS, transfer the system to the 2.5” HDD. If the
system is not transferred, go to Procedure 3. Refer to the DOS Manual for detailed
operation.
If the following message appears on the display, the system program has been
transferred to the HDD.
System Transferred
If an error message appears on the display, perform Check 4.
Check 4
2.5” HDD(s) and the connector(s) of system board may be defective (Refer to the
steps described in Chapter 4,
Replacement Procedures
for disassembling.). Insert
HDD(s) to the connector(s) firmly. If it is (or they are) firmly connected, go to
Procedure 3.
Содержание Portege Z830
Страница 14: ...1 Hardware Overview 1 2 CONFIDENTIAL PORTEGE Z830 Satellite Z830 Series Maintenance Manual 960 883 ...
Страница 38: ...1 Hardware Overview 1 26 CONFIDENTIAL PORTEGE Z830 Satellite Z830 Series Maintenance Manual 960 883 ...
Страница 40: ...Troubleshooting Procedures 2 2 PORTEGE Z830 Satellite Z830 Series Maintenance Manual 960 883 CONFIDENTIAL 2 ...
Страница 106: ...Tests and Diagnostics 3 2 CONFIDENTIAL PORTEGE Z830 Satellite Z830 Series Maintenance Manual 960 883 3 ...
Страница 280: ... CONFIDENTIAL Chapter 4 Replacement Procedures ...
Страница 281: ...4 Replacement Procedures 4 ii CONFIDENTIAL PORTÉGÉ Z830 835 Satellite Z830 Maintenance Manual 960 883 ...
Страница 285: ...4 Replacement Procedures 4 vi CONFIDENTIAL PORTÉGÉ Z830 835 Satellite Z830 Maintenance Manual 960 883 ...
Страница 368: ... CONFIDENTIAL Appendices ...
Страница 369: ...Appendices App ii CONFIDENTIAL PORTEGE Z830 Satellite Z830 Series Maintenance Manual 960 883 ...
Страница 389: ...Appendices Appendix B Board Layout B 10 CONFIDENTIAL PORTEGE Z830 Satellite Z830 Series Maintenance Manual 960 883 ...
Страница 409: ...Appendices Appendix C Pin Assignments C 20 CONFIDENTIAL PORTEGE Z830 Satellite Z830 Series Maintenance Manual 960 883 ...
Страница 419: ...Appendices Appendix E Key Layout E 2 CONFIDENTIAL PORTEGE Z830 Satellite Z830 Series Maintenance Manual 960 883 ...
Страница 421: ...Appendices Appendix F Wiring diagrams F 2 CONFIDENTIAL PORTEGE Z830 Satellite Z830 Series Maintenance Manual 960 883 ...
Страница 427: ...Appendices Appendix I Reliability I 2 CONFIDENTIAL PORTEGE Z830 Satellite Z830 Series Maintenance Manual 960 883 ...