P9 ASD Installation and Operation Manual
Speed 7 Operation Time
Program
Pattern Run
Operation Time
This parameter sets the run-time for
Preset Speed 7
.
This time is effective when used with
Group Speeds
and non-
Group Speeds
.
If the
Auto-Restart
function is activated, the search time required for the
Auto-
Restart
function will be subtracted from the
Operation Time
setting; resulting
in a shorter run time.
Direct Access Number — F546
Parameter Type —
Numerical
Factory Default —
5.0
Changeable During Run —
Yes
Minimum — 0.1
Maximum — 6000.0
Units —
Setting
Speed 8 Operation Time
Program
Pattern Run
Operation Time
This parameter sets the run-time for
Preset Speed 8
.
This time is effective when used with
Group Speeds
and non-
Group Speeds
.
If the
Auto-Restart
function is activated, the search time required for the
Auto-
Restart
function will be subtracted from the
Operation Time
setting; resulting
in a shorter run time.
Direct Access Number — F547
Parameter Type —
Numerical
Factory Default —
5.0
Changeable During Run —
Yes
Minimum — 0.1
Maximum — 6000.0
Units —
Setting
Speed 9 Operation Time
Program
Pattern Run
Operation Time
This parameter sets the run-time for
Preset Speed 9
This time is effective when used with
Group Speeds
and non-
Group Speeds
.
If the
Auto-Restart
function is activated, the search time required for the
Auto-
Restart
function will be subtracted from the
Operation Time
setting; resulting
in a shorter run time.
Direct Access Number — F548
Parameter Type —
Numerical
Factory Default —
5.0
Changeable During Run —
Yes
Minimum — 0.1
Maximum — 6000.0
Units —
Setting
Speed 10 Operation Time
Program
Pattern Run
Operation Time
This parameter sets the run-time for
Preset Speed 10
This time is effective when used with
Group Speeds
and non-
Group Speeds
.
If the
Auto-Restart
function is activated, the search time required for the
Auto-
Restart
function will be subtracted from the
Operation Time
setting; resulting
in a shorter run time.
Direct Access Number — F549
Parameter Type —
Numerical
Factory Default —
5.0
Changeable During Run —
Yes
Minimum — 0.1
Maximum — 6000.0
Units —
Setting
Speed 11 Operation Time
Program
Pattern Run
Operation Time
This parameter sets the run-time for
Preset Speed 11
This time is effective when used with
Group Speeds
and non-
Group Speeds
.
If the
Auto-Restart
function is activated, the search time required for the
Auto-
Restart
function will be subtracted from the
Operation Time
setting; resulting
in a shorter run time.
Direct Access Number — F550
Parameter Type —
Numerical
Factory Default —
5.0
Changeable During Run —
Yes
Minimum — 0.1
Maximum — 6000.0
Units —
Setting
Speed 12 Operation Time
Program
Pattern Run
Operation Time
This parameter sets the run-time for
Preset Speed 12
This time is effective when used with
Group Speeds
and non-
Group Speeds
.
If the
Auto-Restart
function is activated, the search time required for the
Auto-
Restart
function will be subtracted from the
Operation Time
setting; resulting
in a shorter run time.
Direct Access Number — F551
Parameter Type —
Numerical
Factory Default —
5.0
Changeable During Run —
Yes
Minimum — 0.1
Maximum — 6000.0
Units —
Setting
Содержание P9
Страница 1: ...TM P9 ASD Install Op Manual TOSHIBA P9 ASD INSTALLATION OPERATION MANUAL DN 64054 004 February 2013 ...
Страница 2: ......
Страница 3: ...Document Number 64054 004 February 2013 P9 ASD Installation Operation Manual TM ...
Страница 4: ......
Страница 280: ...270 P9 ASD Installation and Operation Manual Figure 38 See Tables 17 and 18 for Actual Dimensions ...
Страница 281: ...P9 ASD Installation and Operation Manual 271 Figure 39 See Tables 17 and 18 for Actual Dimensions ...
Страница 282: ...272 P9 ASD Installation and Operation Manual Figure 40 See Tables 17 and 18 for Actual Dimensions ...
Страница 285: ...P9 ASD Installation and Operation Manual 275 Figure 43 See Table 18 for the associated device Dimensions are in in cm ...
Страница 304: ...294 P9 ASD Installation and Operation Manual W W T3 16 Warranty Card 2 W Phase Over Current 265 ...
Страница 305: ......