180
P9 ASD Installation and Operation Manual
S-Pattern Acceleration Lower-Limit Adjustment
Program
Special
Accel/Decel Special
During an
S-Pattern
1
or
2
sequence, this parameter setting modifies the
acceleration rate for the lower part of the acceleration curve by the percentage
set here.
This function is commonly used with transportation and lifting applications.
See
for additional information on this parameter.
Direct Access Number — F506
Parameter Type —
Numerical
Factory Default —
10
Changeable During Run —
Yes
Minimum — 0
Maximum — 50
Units — %
S-Pattern Acceleration Upper-Limit Adjustment
Program
Special
Accel/Decel Special
During an
S-Pattern
1
or
2
sequence, this parameter setting modifies the
acceleration rate for the upper part of the acceleration curve by the percentage
set here.
This function is commonly used with transportation and lifting applications.
See
for additional information on this parameter.
Direct Access Number — F507
Parameter Type —
Numerical
Factory Default —
10
Changeable During Run —
Yes
Minimum — 0
Maximum — 50
Units — %
S-Pattern Deceleration Lower-Limit Adjustment
Program
Special
Accel/Decel Special
During an
S-Pattern
1
or
2
sequence, this parameter setting modifies the
deceleration rate for the lower part of the deceleration curve by the percentage
set here.
This function is commonly used with transportation and lifting applications.
See
for additional information on this parameter.
Direct Access Number — F508
Parameter Type —
Numerical
Factory Default —
10
Changeable During Run —
Yes
Minimum — 0
Maximum — 50
Units — %
S-Pattern Deceleration Upper-Limit Adjustment
Program
Special
Accel/Decel Special
During an
S-Pattern
1
or
2
sequence, this parameter setting modifies the
deceleration rate for the upper part of the deceleration curve by the percentage
set here.
This function is commonly used with transportation and lifting applications.
See
for additional information on this parameter.
Direct Access Number — F509
Parameter Type —
Numerical
Factory Default —
10
Changeable During Run —
Yes
Minimum — 0
Maximum — 50
Units — %
Acceleration Time 3
Program
Special
Accel/Decel 1 – 4 Settings
This parameter specifies the time in seconds for the output of the ASD to go
from 0.0 Hz to the
Maximum Frequency
for the
3 Acceleration
profile. The
Accel/Decel pattern may be set using
. The minimum Accel/Decel time
may be set using
.
Note:
An acceleration time shorter than the load will allow may cause
nuisance tripping and mechanical stress to loads.
Automatic
Accel/Decel
,
Stall
, and
Ridethrough
settings
may lengthen the
acceleration times.
Direct Access Number — F510
Parameter Type —
Numerical
Factory Default —
(ASD-Dependent)
Changeable During Run —
Yes
Minimum — 0.1
Maximum — 6000
Units — Seconds
Содержание P9
Страница 1: ...TM P9 ASD Install Op Manual TOSHIBA P9 ASD INSTALLATION OPERATION MANUAL DN 64054 004 February 2013 ...
Страница 2: ......
Страница 3: ...Document Number 64054 004 February 2013 P9 ASD Installation Operation Manual TM ...
Страница 4: ......
Страница 280: ...270 P9 ASD Installation and Operation Manual Figure 38 See Tables 17 and 18 for Actual Dimensions ...
Страница 281: ...P9 ASD Installation and Operation Manual 271 Figure 39 See Tables 17 and 18 for Actual Dimensions ...
Страница 282: ...272 P9 ASD Installation and Operation Manual Figure 40 See Tables 17 and 18 for Actual Dimensions ...
Страница 285: ...P9 ASD Installation and Operation Manual 275 Figure 43 See Table 18 for the associated device Dimensions are in in cm ...
Страница 304: ...294 P9 ASD Installation and Operation Manual W W T3 16 Warranty Card 2 W Phase Over Current 265 ...
Страница 305: ......