background image

EN

– 8 –

„

Operation section

Once the settings have been configured, all you need to do is push the 

 button from then on.

1

 button (Fan speed select button)

Selects the desired Fan speed.
* Not available for the concealed duct high static 

pressure and fresh air intake type. Only “High” is 
displayed.

2

 button (Timer set button)

Use to setup the timer.

3

 button (TEST button)

Use only for service. 
(During normal operation, do not use this button.)

4

 button

Use when a ventilator (commercially-available) is 
connected. Push the button to turn on / off the 
ventilator. Turning on / off the air-conditioner also 
turns on / off the ventilator. 
*

No ventilator is connected if 

” appears on 

the remote controller display after pushing the 

 button.

5

 button (Filter reset button)

Resets “

 FILTER” indication after cleaning.

6

 button (Power save operation)

Use to initiate power saving mode.

7

 button

Use to select automatic swing or fixed louver 
position.
* Not available for concealed duct, slim duct, floor 

concealed and floor standing cabinet fresh air 
intake types.

8

Operation lamp

Lights up during running.
Blinks when an error occurs or the protective 
device activates.

9

 button

Turns on the unit when pushed, and turns off when 
pushed again.

10

 button (Operation mode select button)

Selects desired operation mode.

1 8

3

5

2

10

7

12

11

SWING/FIX

11

 button (Unit/Louver select button)

Selects a unit number (left) and louver number 
(right).

UNIT button:

 

If two or more indoor units are controlled by one 
remote controller, use this button to select a unit to 
adjust its air blow direction.

LOUVER button:

 (4-way cassette type 2H series 

only)
Selects a louver to control when adjusting the 
louver lock setting or wind direction setting 
separately for each louver.

12

 button

Adjusts the set temperature.
Select the desired set point by pushing  TEMP. 

 or  TEMP. 

OPTION:

Remote controller sensor

Normally the temperature sensor of the indoor unit 
senses the temperature. The temperature around the 
remote controller can also be sensed. For details, 
contact your dealer.
* Do not use the function when the air conditioner is 

controlled in a group.

1 8

3

5

2

10

7

12

11

UNIT  LOUVER

15-EN

16-EN

Содержание MMY-MAP0501HT8-E

Страница 1: ...MMY MAP0801HT8ZG E MMY MAP1001HT8 E MMY MAP1001HT8Z E MMY MAP1001HT8ZG E MMY MAP1201HT8 E MMY MAP1201HT8Z E MMY MAP1201HT8ZG E Cooling Only Model MMY MAP0501T8 E MMY MAP0501T8Z E MMY MAP0501T8ZG E MMY MAP0601T8 E MMY MAP0601T8Z E MMY MAP0601T8ZG E MMY MAP0801T8 E MMY MAP0801T8Z E MMY MAP0801T8ZG E MMY MAP1001T8 E MMY MAP1001T8Z E MMY MAP1001T8ZG E MMY MAP1201T8 E MMY MAP1201T8Z E MMY MAP1201T8ZG E...

Страница 2: ...knowledge related to this work The qualified installer who is allowed to do the refrigerant handling and piping work involved in installation relocation and removal has the qualifications pertaining to this refrigerant handling and piping work as stipulated by the local laws and regulations and he or she is a person who has been trained in matters relating to refrigerant handling and piping work o...

Страница 3: ...breaker positions In the event that error has occurred in the air conditioner set the circuit breaker to the OFF position and contact a service person If you install the unit in a small room take appropriate measures to prevent the refrigerant from exceeding the limit concentration even if it leaks Consult the dealer from whom you purchased the air conditioner when you implement the measures Accum...

Страница 4: ... Installation fuse all types can be used must be used for the power supply line of this air conditioner Installation Certainly lay the drain hose for perfect draining Bad drainage may cause flooding in the house and getting furniture wet Make sure to connect the air conditioner to an exclusive power supply of the rated voltage otherwise the unit may break down or cause a fire Confirm that the outd...

Страница 5: ... H E Fresh Air Intake MMD AP HFE For details on these models read the owner s manuals that come with the indoor units Air to Air Heat Exchanger with DX Coil Unit MMD VNK HEXE MMD VN HEXE For details on these models read the owner s manuals that come with the indoor units High wall compact MMK AP MH E For details on these models read the owner s manuals that come with the indoor units High wall MMK...

Страница 6: ...e room is taken in through here Discharge louver Controls discharge air directions 2 way Cassette Type 1 way Cassette Type MMU AP007 YH to AP012 YH MMU AP015 SH to AP024 SH Return air grille Air in the room is taken in through here Earth screw Equipped on the electrical control box Air filter Filters out dust Inside the return air grille Discharge louver Controls discharge air directions Air filte...

Страница 7: ...anding Cabinet Type Floor Standing Concealed Type Floor Standing Type Air filter Filters out dust Inside the return air grille Discharge louver Controls discharge air directions Return air grille Air in the room is taken in through here Earth screw Equipped on the electrical control box Air filter Filters out dust Inside the return air grille Discharge louver Controls discharge air directions Eart...

Страница 8: ...r sensor indicator Displayed when the remote controller sensor is used 12 Pre heat indicator Displayed when the heating mode is energized or defrost cycle is initiated While this indication is displayed the indoor fan stops or operate in fan mode 13 No function indicator Displayed when the function requested is not available on that model 14 Fan speed indicator Indicates the selected fan speed 15 ...

Страница 9: ...d and floor standing cabinet fresh air intake types 8 Operation lamp Lights up during running Blinks when an error occurs or the protective device activates 9 button Turns on the unit when pushed and turns off when pushed again 10 button Operation mode select button Selects desired operation mode 1 8 3 5 2 9 10 6 7 12 4 11 SWING FIX 11 button Unit Louver select button Selects a unit number left an...

Страница 10: ...The fan speed selection function is not available for the concealed duct high static type Fan speed is fixed and the indicator is fixed to High SET TIME TIMER SET TEST FILTER RESET TEMP CL FAN SAVE SWING FIX VENT MODE ON OFF UNIT LOUVER 1 2 Heat pump model Heat Dry Cool Fan Dehumidify Cooling only model Dry Cool Fan Dehumidify Low Medium High Auto Changing the set temperature 1 Push the TEMP butto...

Страница 11: ...ing near machines emitting high frequency waves Not suitable for chemical plants such as liquefied carbon dioxide refrigerant plants Do not install the air conditioner in locations where iron or other metal dust is present If iron or other metal dust adheres to or collects on the interior of the air conditioner it may spontaneously combust and start a fire A failure may occur in certain locations ...

Страница 12: ...ioner If the protective device activates the unit s running stops and the operation lamp blinks When the protective device activates the indicator and the check code are displayed on the remote controller The protective device may activate in the following cases During cooling When the air intake or air discharge of the outdoor unit is blocked When strong wind blows continuously against the air di...

Страница 13: ...COOL DRY operation the louver does not stop as it directs downward If stopping the louver as it directs downward during swing operation it stops after moving to the third position from the highest position Unit select When two or more indoor units are controlled with one remote controller the louver direction can be set for each indoor unit by selecting them individually To set louver direction in...

Страница 14: ...display Unit No 1 1 Unit No 1 2 Unit No 1 3 Unit No 1 4 Swing code Swing Horizontal Downward Downward Horizontal Downward Downward Horizontal Horizontal Cyclic swing Recommended for cooling All four louvers swing at different times like waves Setting the louver lock 1 Push and hold the button right side of the button for at least 4 seconds while running is stopped blinks When no unit number is dis...

Страница 15: ...ction setting 0000 Smudging reduction position reduces ceiling smudging factory default 0002 Cold draft position Less directly expose your body to cool air 0000 SET DATA UNIT LOUVER Unit No 1 1 Unit No 1 2 Unit No 1 3 Unit No 1 4 No display 4 way cassette type The louver automatically closes when running is stopped In pre heating mode the louver points upward The swing indication appears on the re...

Страница 16: ... GOOD GOOD Ceiling type Vertical adjustment The louver automatically points upward when running is stopped In pre heating mode the louver points upward The swing indication appears on the remote controller even in pre heating mode but the actual swing starts only after pre heating is complete Horizontal adjustment 1 way cassette YH series and floor standing types Setting the direction and swinging...

Страница 17: ... louvers slightly and point them in your preferred directions 1 2 In this case do not use the auto swing function Floor standing cabinet type Changing the air discharge Follow the procedure below to change the air discharge 1 Remove the two fixing screws of the air discharge The fixing screws are to be reused 2 Insert your hand into the air discharge and pull it up slightly then remove the air dis...

Страница 18: ...et bulb temp CAUTION Room relative humidity less than 80 If the air conditioner operates in excess of this figure the surface of the air conditioner may cause dewing Heating operation Outdoor temperature 20 C to 15 5 C Wet bulb temp Room temperature 15 C to 28 C Dry bulb temp Check periodically Do not cool down too much Close 10Maintenance WARNING For daily maintenance including Air Filter cleanin...

Страница 19: ...hapter Wipe with a dry soft cloth If heavily stained wipe off dirt with a cloth soaked in lukewarm water Do not use water to wipe the remote controller Do not use benzine thinner scouring powder chemical cloth etc as those may cause deformation or breakage If unused for over a month Leave the fan on for half a day or so to dry the inside Turn off the main power switch Clean the air filter and then...

Страница 20: ... not cooled or warmed sufficiently Is the air intake or air discharge of the outdoor unit obstructed Are any door or window open Is the air filter clogged with dust Is discharge louver of the indoor unit set at appropriate position Is air selection set to LOW MED and is the operation mode set to FAN Is the setup temp the appropriate temperature Are COOL and HEAT selected simultaneously indication ...

Страница 21: ...APAN Authorized Representative TCF holder Nick Ball Toshiba EMEA Engineering Director Toshiba Carrier UK Ltd Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom Hereby declares that the machinery described below Generic Denomination Air Conditioner Model type Heat Pump Model MMY MAP0501HT8 E MMY MAP0501HT8Z E MMY MAP0501HT8ZG E MMY MAP0601HT8 E MMY MAP0601HT8Z E MMY MAP0...

Страница 22: ... 21 MEMO ...

Страница 23: ... 22 MEMO ...

Страница 24: ... manufacturer TOSHIBA CARRIER CORPORATION Address city country 336 Tadehara Fuji shi Shizuoka ken 416 8521 Japan Name of the Importer Distributor in EU Toshiba Carrier UK Ltd Address city country Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom ...