background image

– 4 –

contact a qualified service person. Take steps to ensure that the 

power will not be turned on (by marking “out of service” near the 

circuit breaker, for instance) until qualified service person arrives. 

Continuing to use the hot water module in the error status may cause 

mechanical problems to escalate or result in electric shocks, etc.

• If you have discovered that the fan grille is damaged, do not approach 

the outdoor unit but set the circuit breaker to the OFF position, and 

contact a qualified service person to have the repairs done. Do not set 

the circuit breaker to the ON position until the repairs are completed.

• If you have discovered that there is a danger of the outdoor and the 

hot water module unit’s toppling over, do not approach the outdoor 

and the hot water units but set the circuit breaker to the OFF position, 

and contact a qualified installer or a qualified service person to have 

the improvements or refitting done. Do not set the circuit breaker to 

the ON position until the improvements or refitting is completed.

• Do not customize the unit. Doing so may result in fire, electric shock, 

etc.

Relocation

• When the hot water module is to be relocated, do not relocate it 

yourself but contact a qualified installer or a qualified service person. 

Failure to relocate the hot water module properly may result in electric 

shocks and/or a fire.

(*1) Refer to the “Definition of Qualified Installer or Qualified Service Person.”

CAUTION

To disconnect the appliance form the main supply

• This appliance must be connected to the mains by means of a switch 

with a contact separation of at least 

3 mm

.

Installation

• Certainly lay the drain hose for perfect draining. Bad drainage may 

cause flooding in the house and getting furniture wet.

• Make sure to connect the hot water module to an exclusive power 

supply of the rated voltage, otherwise the unit may break down or 

cause a fire.

• Confirm that the outdoor unit and the hot water module are fixed on 

the base. Otherwise, falling down of the units or other accidents may 

occur.

Operation

• Do not use this hot water module for special purpose such as 

preserving food, precision instruments, art objects, breeding animals, 

car, vessel, etc.

• Do not touch any switches with wet finger, otherwise you may get an 

electric shock.

• If the air conditioner system (including hot water module) will not be 

used for a considerably long time, turn off the main switch or the 

circuit breaker, for safety.

• To make the hot water module operate in its original performance, 

operate it within the range of the operating temperature specified in 

the instructions. Otherwise it may cause a malfunction, or water leak 

from the unit.

• Prevent any liquid from falling into the remote controller. Do not spill 

juice, water or any kind of liquid.

• Do not wash the hot water module. Doing so may result in electric 

shock.

• Check whether the installation base and other equipment have 

become deteriorated after being used for a long time. Leaving them 

such condition may result in the unit’s falling down and causing injury. 

• Do not leave flammable sprays or other flammable materials near the 

hot water module, and do not spray flammable aerosol directly to the 

hot water module. They may catch fire.

7-EN

8-EN

Содержание MMW-UP0271LQ-E

Страница 1: ...Indoor Unit Model name Mid temperature Hot Water Module MMW UP0271LQ E MMW UP0561LQ E HOT WATER MODULE MULTI TYPE Owner s Manual For commercial use R410A English ...

Страница 2: ...ent destruction of the ozone layer This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user mai...

Страница 3: ...t water modules made by Toshiba Carrier Corporation or alternatively he or she has been instructed in such operations by an individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge related to these operations The qualified service person who is allowed to do the electrical work involved in installation repair relocation and removal has the qualifications...

Страница 4: ... and becomes concentrated around the unit a fire may occur Be sure to use the company specified products for the separately purchased parts Use of non specified products may result in fire electric shock water leakage etc Have the installation performed by a professional Confirm that earthing is performed correctly Operation Inside the air conditioner and the hot water module are high voltage area...

Страница 5: ...nce must be connected to the mains by means of a switch with a contact separation of at least 3 mm Installation Certainly lay the drain hose for perfect draining Bad drainage may cause flooding in the house and getting furniture wet Make sure to connect the hot water module to an exclusive power supply of the rated voltage otherwise the unit may break down or cause a fire Confirm that the outdoor ...

Страница 6: ...compressor always confirm that the hot water module is operable power on address fixed communication wiring complete Failure to do this will cause the heat exchanger in the hot water module to freeze rupture and leak water Information on the transportation handling and storage of the carton Examples of indication on the carton Symbol Description Symbol Description Symbol Description Keep dry Do no...

Страница 7: ...entral remote controller If the use of the remote controller is prohibited by the central control blinks when the ON OFF Setting or Menu button on the remote controller is pushed and the buttons do not function Settings that can be configured on the remote controller differ depending on the mode of the central control For details read the Owner s Manual of the central remote controller 3 Setting i...

Страница 8: ... according to the setting screen 8 ON OFF button Menu items Available function No function 1 Wind Direction 2 Individual louver 3 Louver setting 4 Off reminder timer 5 Schedule timer 6 Night operation 7 Filter sign 8 Auto grille 9 Energy saving 10 Initial setting 11 Ventilation 12 Soft cooling setting 13 Occupancy sensor 14 Power consumption 15 Information Switching between the normal display and ...

Страница 9: ... Select the temperature Push the setting button to adjust the temperature Heating Menu button Setting button ON OFF button Operation mode Setting range Factory default Heating 25 to 50 C 35 C 5 OFF timer operation OFF timer the indoor unit stops running when the set time is reached 1 OFF timer button Push the OFF timer button when the Hot water module is running and turn on while and the timer ind...

Страница 10: ... Noise may become a problem 7 Notes on operations and performance Check before operation Turn on the power switch at least 12 hours before starting operation Make sure the earth wire is securely connected Defrosting during heating If frost falls on the outdoor unit during heating defrosting is automatically performed for approximately 2 10 minutes to increase the heating effect The Hot water modul...

Страница 11: ...ified service person particularly following models as the maintenance requires high place work Cleaning the hot water module and remote controller Ask qualified service person to clean the hot water module for the models listed in the warning on the top of this chapter Wipe with a dry soft cloth Do not use benzine thinner scouring powder chemical cloth etc as those may cause deformation or breakag...

Страница 12: ...cking sound is heard when the hot water module is powered on When the power is on sound is heard when the expansion valve is running LCD blurs when it is touched LCD may be temporarily blurred due to static electricity Need to check again Operates or stops automatically Is the timer ON or OFF Not operating Is it a power failure Is the power switch OFF Is the power supply fuse or circuit breaker bl...

Страница 13: ... troubleshooting history mode DO NOT push the Menu button for over 10 seconds doing so deletes the entire troubleshooting history of the indoor unit 3 After you have finished checking push the ON OFF button to return to the regular mode If the air conditioner including Hot water module is operating it remains operated even after the ON OFF button has been pushed To stop its operation push the ON O...

Страница 14: ...E S A S Route de Thil 01120 Montluel FRANCE Hereby declares that the machinery described below Generic Denomination Hot Water Module Model type MMW UP0271LQ E MMW UP0561LQ E Commercial name Super Modular Multi System Air Conditioner Super Heat Recovery Multi System Air Conditioner Mini Super Modular Multi System Air Conditioner MiNi SMMS series Complies with the provisions of the Machinery Directi...

Страница 15: ...EH99966201 DH91307701 ...

Отзывы: