– 27 –
Lite-Vision plus Remote Controller
Installation Manual
5. DN setting
Perform the advanced settings for the air conditioner.
Carry out the setting operation while the indoor unit is stopped. (Turn off the air conditioning unit before starting the
setting operation.)
1
Push the [
∧
] / [
∨
] button to select
“5. DN setting” on the “Field setting menu”
screen, then push the “
Set” [
F2] button.
Æ
The fan and louver of the indoor unit operate.
When the group control is used, the fan and
louver of the selected indoor unit operate.
Æ
Move the cursor to select “DN code” with the
“
<
” [
F1] button, then set “DN
code” with the [
∧
] / [
∨
] button.
Æ
Move the cursor to select “data” with the
“
>
” [
F2] button, then set “data”
with the [
∧
] / [
∨
] button.
2
Refer to the Installation Manual supplied
with the indoor unit or service manual for
details about the DN code and data.
3
Push the [
MENU] button to set the other
DN codes. After “Continue?” is displayed
on the screen, push the “
Yes”
[
F1] button.
4
Push the “
No” [
F2] button to
finish the setting operation. “ ” appears on
the screen for a while, then the screen
returns to the “Field setting menu” screen.
Æ
Pushing the “
No” [
F2] button
displays the unit selection screen when the
group control is used. Push the [
CANCEL]
button on the unit selection screen to finish the
setting operation. “ ” appears on the screen for
a while, then the screen returns to the “Field
setting menu” screen.
DN setting
Code
(DN)
Data
Return
10
0000
Fix
<
>
Set
<
>
Yes
No
No
DN setting
Code
(DN)
Data
Return
10
0001
Fix
<
>
Return
Continue?
No
Yes
DN setting