IPMI / BMC IP ADDRESS
15-2
Installation Manual June, 2011
•
Remote access to text-based, graphic-based system
information, including BIOS configurations and OS operation
information (KVM)
•
Remote management of utility/software applications
IPMI provides Network Management Security via remote access/console
redirection.
Key features include:
•
User authentication enhancement
•
Encryption support enhancement, allowing for password
configuration security to protect sensitive data transferring via
Serial over LAN.
•
The IPMI supports the following Management tools: IPMIView, CLI
(Command Line Interface)
•
RMCP+ protocol supported
IPMI / BMC IP ADDRESS
The IP address of the IPMI port should have be set during the New
System Installation process. Skip to
if the IPMI address was setup
during installation.
If the address was not setup use the following steps to connect a PC to
the IPMI using the default address settings:
IP Address: 192.168.254.251, Subnet Mask: 255.255.255.0,
Default Gateway: 192.168.254.1
1. Login to Enterprise Manager. Select
Maintenance > System
Maintenance > Hardware Monitoring
.
2. Select the
BMC Network Adapter
tab.
3. Assign the
IP Address
, If static; assign Subnet Mask and Default
Gateway.
4. Click on the
Save
icon.
5. Connect the BMC to the LAN or WAN.
6. Connect IP
edge
Server (BMC LAN adapter, not eth0 or eth1) and the
PC to the WAN/LAN.
7. Launch a java-enabled browser (e.g. Internet Explorer) on the PC
and access http://BMC LAN IP address (e.g. http://192.168.254.251)
8. Enter the following user name and password
User Name: ADMIN
Password: ADMIN
Important!
This process will login in to the server remote terminal.
Change the User Name and Password for better system
security. Record the User Name and Password. There is
no password recovery process. Use this terminal only
under the direction of a Toshiba engineer.
Содержание IPedge
Страница 1: ...TOSHIBA Telecommunication Systems Division Installation Manual Title Page June 2011 ...
Страница 18: ...This page is intentionally left blank ...
Страница 32: ...This page is intentionally left blank ...
Страница 46: ...This page is intentionally left blank ...
Страница 74: ...This page is intentionally left blank ...
Страница 78: ...This page is intentionally left blank ...
Страница 88: ...This page is intentionally left blank ...
Страница 92: ...This page is intentionally left blank ...
Страница 96: ...This page is intentionally left blank ...
Страница 140: ...MEDIANT 1000 CONFIGURATION IPedge Configuration 12 20 Installation Manual June 2011 ...
Страница 165: ...Server Based Call Manager Configuration Assign Users to User Groups Installation Manual June 2011 13 25 ...
Страница 187: ...EM SERVER FAN REPLACEMENT Power UP Server Installation Manual June 2011 15 11 Figure 15 2 EM Server Fan Location ...
Страница 196: ...THIS IS THE END OF THE DOCUMENT ...