10
•
EE lens
The IRIS extension cable (optional) is usable for the EE lens. Use the connector HR10A-
7P-4P of HIROSE when the IRIS extension cable is selected. For connections, follow the
instruction below.
When the IRIS extension cable is used under
the right condition, the cable automatically
converts to connection for the EE lens in
Table 1. See the Chapter OPTIONS for the IRIS
extension cable.
Notes:
•
Current consumption must be 50 mA or less.
•
Avoid an incorrect connection or short-circuit.
5. WHEN USING THE CAMERA WITH THE CAMERA UNIT FIXED
The camera control unit can be directly mounted by using M3 screws if the four rubber
feet are removed on bottom of the control unit. When mounting directly as described
above, do not use longer screws. If the screws enter by more than 5 mm from the control
unit mounting surface, they will cause a short-circuit inside the control unit. For details of
screw hole locations, refer to the exterior dimensions of the camera control unit.
EE lens connector
HR10A-7P-4P
1.
Power (+)
2.
GND
3.
Video signal
4.
Unconnected or ground