
October 2000 © TOSHIBA TEC
2 - 15
GD1080/1090
SELF-DIAGNOSIS MODE
GD1080/1090
SELF-DIAGNOSIS MODE
2 - 14
October 2000 © TOSHIBA TEC
Code
Adjustment
Function
Setting
Default
Code
AS AU HK US DE GB IT BE NL FI ES AT CH SE DK NO PT FR GR PL HU CZ TR ZA
Set the dial tone frequency to be
detected for the PSTN.
Set the time for a tone sounds to
be determined as dial tone for the
PSTN.
Set the interruption time for the
PSTN to be ignored during LCC.
Set the interruption time for the
PSTN to be ignored during DTC.
Select which is to be used for the
PSTN, DTC or LCC.
Set how long the dial tone detec-
tion is performed.
Set the dial tone frequency to be
detected for the PABX.
Set the time for a tone sounds to
be determined as dial tone for the
PABX.
Set the interruption time for the
PABX to be ignored during LCC.
Set the interruption time for the
PABX to be ignored during DTC.
Select which is to be used for the
PABX, DTC or LCC.
Set how long the dial tone detec-
tion is performed.
Set the busy tone frequency to be
detected for the PSTN and PABX.
Set the time to wait for a response
from the receiver after dialing is
completed.
Set the definition of the DP dial.
Normal: n
Shift: n+1
Reverse: 10-n
n=Dial No.
When dialing is interrupted because
any of the settings for DTC/LCC is
not satisfied during redialing, that
redialing is ignored since it is con-
sidered as an internal retry.
0: 300-600Hz 1: 300-650Hz
2: 390-550Hz 3: 400-450Hz
4: 350-480Hz 5: 300-500Hz
6: Reserved 7: Reserved
0: 2sec 1: 800ms 2: 400ms 3: 1sec
4: 1.3sec 5: 1.8sec 6: 2.5sec
7: 500ms
0: OFF 1: 50ms 2: 100ms 3: 200ms
0: OFF 1: 70ms 2: 160ms 3: 240ms
0: BZT(DTC/LCC) 1: LCC 5sec
2: DTC only 3: FRN(LCC/DTC)
4: DTC(JPN&USA) 5: NO DTC&LCC
0: 20sec 1: 10sec 2: 8sec 3: 15sec
4: 3.3sec
0: 300-600Hz 1: 300-650Hz
2: 390-550Hz 3: 400-450Hz
4: 350-480Hz 5: 300-500Hz
6: Reserved 7: Reserved
0: 2sec 1: 800ms 2: 400ms 3: 1sec
4: 1.3sec 5: 1.8sec 6: 2.5sec 7: 150ms
0: OFF 1: 50ms 2: 100ms 3: 200ms
0: OFF 1: 70ms 2: 160ms 3: 240ms
0: BZT(DTC/LCC) 1: LCC 5sec
2: DTC only 3: FRN(LCC/DTC)
4: DTC(JPN&USA) 5: NO DTC&LCC
0: 20sec 1: 10sec 2: 8sec 3: 15sec
4: 3.3sec
0: Not detected 1: 300-600Hz
2: 350-550Hz 3: 300-500Hz
4: 300-700Hz
0: 60sec 1: 35sec 2: 90sec 3: 55sec
4: 115sec
0: Normal 1: Shift 2: Reverse
0: OFF 1: ON
220
221
222
223
224
225
226
227
228
229
230
231
232
236
245
247
DTC frequency (PSTN)
(Line 2)
DTC time (PSTN) (Line 2)
LCC allowed gaps (PSTN)
(Line 2)
DTC allowed gaps (PSTN)
(Line 2)
DTC/LCC for PSTN
(Line 2)
DTC time out (PSTN)
(Line 2)
DTC frequency (PABX)
(Line 2)
DTC time (PABX) (Line 2)
LCC allowed gaps (PABX)
(Line 2)
DTC allowed gaps (PABX)
(Line 2)
DTC/LCC for PABX
(Line 2)
DTC time out (PABX)
(Line 2)
BTC frequency(Line 2)
Dial T1 timer (Line 2)
Dial information (Line 2)
Internal retry (Line 2)
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
220
0
0
0
3
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
0
0
221
0
0
0
3
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
0
0
222
0
0
0
3
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
0
0
223
5
5
5
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
5
5
224
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
225
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
226
0
0
0
6
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
0
0
227
0
0
0
0
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
0
0
228
0
0
0
0
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
0
0
229
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
230
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
231
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
232
0
3
0
3
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
0
0
236
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
2
0
0
0
0
0
0
0
0
245
0
0
0
0
1
1
0
0
0
0
0
1
0
0
1
1
0
0
0
0
0
0
0
0
247