— 3 —
ALIGNMENT PROCEDURE
BASE UNIT / TRANSMITTER
Test Equipment Required and Connections
•
Oscilloscope
•
Dummy Load, 50-ohm
•
Frequency Counter
•
AC Power Supply: 120V, 60Hz (With AC Adapter)
•
Digital Voltmeter
Preset
a) Set T/P SW to Pulse Mode.
b) Turn on AC power while the Page key is being depressed.
c) Release the Page key about 2 seconds later, then the TX Mode is entered (CH21).
Alignment Procedure
Step
Adjustment
Remarks
1
L10
Connect the oscilloscope across a 50-ohm load to RF test point.
Set the digital voltmeter at the test point of TX VCO.
Adjust L10 to indicate DC 2.8
±
0.05 V (VCO).
2
Connect the frequency counter across a 50-ohm dummy load to RF test
point. Make sure that the frequency is 46.770 MHz
±
1500 Hz.
Alignment Point Location on Main (Base Unit) PCB
−
+
AC Adapter
(120V 60Hz)
Base Unit
J2
DC IN 9V
JACK
RF Test
Point
Dummy Load
(50-ohm)
Frequency Counter
Oscilloscope
Digital Voltmeter
TX VCO
Test Point
TX VCO Test Point
DC IN 9V Jack
T/P SW
P
T
J2
S1
L10
RF Test Point
L1
Содержание FT-7807R
Страница 1: ...CORDLESS TELEPHONE SERVICE MANUAL PUBLISHED IN JAPAN Jun 1998 FT 7807R FILE NO 2B0 9803 ...
Страница 8: ... 7 ...
Страница 9: ... 8 ...
Страница 10: ... 9 10 SCHEMATIC DIAGRAMS TEST POINT RF TEST POINT RX VCO TEST POINT TX VCO TEST POINT Discriminator ...
Страница 11: ... 11 12 TEST POINT RF TEST POINT RX VCO TEST POINT Discriminator TEST POINT TX VCO ...
Страница 26: ... 27 ...
Страница 27: ... 28 ...
Страница 28: ... 29 ...
Страница 29: ... 30 EXPLODED VIEW AND MECHANICAL PARTS LIST Base Unit ...
Страница 31: ... 32 Handset ...
Страница 52: ...MECHANICAL PARTS LIST ...