41
SPECIFICATIONS
MEASUREMENT CONDITIONS
Standard Voltage
:Portable Unit
.... DC 2.4V ± 0.05V
:Base Unit
.... AC 120V ± 3V 60Hz
Temperature
:25
˘
± 5
˘
Channel
FCC CH
Portable(TX Frequency)
Base(TX Frequency)
1
48.760 MHz
43.720 MHz
2
48.840 MHz
43.740 MHz
3
48.860 MHz
43.820 MHz
4
48.920 MHz
43.840 MHz
5
49.020 MHz
43.920 MHz
6
49.080 MHz
43.960 MHz
7
49.100 MHz
44.120 MHz
8
49.160 MHz
44.160 MHz
9
49.200 MHz
44.180 MHz
10
49.240 MHz
44.200 MHz
11
49.280 MHz
44.320 MHz
12
49.360 MHz
44.360 MHz
13
49.400 MHz
44.400 MHz
14
49.460 MHz
44.460 MHz
15
49.500 MHz
44.480 MHz
16
49.670 MHz
46.610 MHz
17
49.845 MHz
46.630 MHz
18
49.860 MHz
46.670 MHz
19
49.770 MHz
46.710 MHz
20
49.875 MHz
46.730 MHz
21
49.830 MHz
46.770 MHz
22
49.890 MHz
46.830 MHz
23
49.930 MHz
46.870 MHz
24
49.990 MHz
46.930 MHz
25
49.970 MHz
46.970 MHz
4. Tel. Line Voltage/Load
: DC 48V ± 2V / 600 OHMS
5. Ring Frequency
: 20 Hz
6. Ring Duration
: 2 Sec ON, 4 Sec OFF
7. Standard Modulation
: 1KHz ± 3KHz Dev.
8. Method of Measurement
: According to EIA Standard RS-316A
9. Portable RX Load
: 150 OHMS
OPERATING TEMPERATURE:
-10 ~ +50
˘
STORAGE TEMPERATURE:
-20 ~ +60
˘
Содержание FT-7007LBR
Страница 1: ... PUBLISHED IN JAPAN Nov 1998 0 10 2 3 456789 FT 7007LR FT 7007LBR ...
Страница 8: ...7 BLOCK DIAGRAMS Base Unit ...
Страница 9: ...8 Handset ...
Страница 10: ...9 10 SCHEMATIC DIAGRAMS Base Unit RF TEST POINT RX VCO TEST POINT TX VCO TEST POINT DISCRI TEST POINT ...
Страница 11: ...11 12 Handset RX VCO TEST POINT RF TEST POINT TX VCO TEST POINT DISCRI TEST POINT ...
Страница 26: ...27 WIRING DIAGRAM Handset ...
Страница 27: ...28 EXPLODED VIEWS AND MECHANICAL PARTS LIST Base Unit 4 12 7 3 9 1 5 11 MAIN ASSY 2 10 8 ANTENNA 6 10 10 ...
Страница 43: ......