background image

TIC-LF232A 

 

 

7

Table 1. Specification Code for converters (LF232) 

Model Specification 

Code 

1 2 3 4 5 6 7 8 9 10 11 12 13 14

Contents 

F 2 3 2   

      Separate type converter 

   

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

A   

 

 

 

 

 

 

Purpose 

Standard 

   

 

 

 

 

 

A

 

B

 

 

 

 

 

  Compatible detectors  (Note1,2,3) 

Medium to small-size detectors: 
   Meter size 1/10” to 18” (2.5 to 450 mm)  
Large-size detectors: 
   Meter size 28” to 120” (700 to 3000 mm) 

   

 

 

 

 

 


 

 

 

 

 

  Mounting nuts and bolts 

Panel, wall mounting (BNP material : SUS304) 
Pipe mounting (BNP material : SUS304) 

   

 

 

 

 

 

 

 

 

 
 
 

 

 

 

  Digital input/output 

Current output  

+ Digital output points (1 point) 

Current output 
    + Digital output points (4 points) + Digital input points  (2 points) 

   

 

 

 

 

 

 

 

 

 

 

  Communication function 

    HART communication 

   

 

 

 

 

 

 

 

 


 

 

  Power supply 

100Vac-240Vac, 50/60Hz  (Note 2) 
24Vdc  (Note 3) 

   

 

 

 

 

 

 

 

  A   

  Standard 

 
 

Note 1: For applicable detector code, select one from the following table. 

To combine with an existing detector, select one depending on the type of replaceable converters. 

For combination with detectors not listed below, contact Toshiba.

 

 

Applicable 

detector code 

Applicable 

detector 

Applicable detector 

(discontinued model) 

Replaceable converters 

 LF470 type 

334,  
335 type (Converters of 
types shown right) 

372, LF200, LF220, LF420, 
LF230* A type 

LF150 type 

337,  
335 type (Converters of 
types shown right) 

373, 378, LF230* B type 

 

Note 2: When the 7th digit is “B” and power supply specification code is “1”, power supply specification is 100 to 

120VAC. 

Note 3: 24VDC can be specified only when the 7th digit is “A”. 

Содержание Electromagnetic Flowmeter Converter TIC-LF232A

Страница 1: ... HARTprotocol Highway Addressable Remote Transducer is a communication protocol for industrial sensors recommended by the HCF HART Communication Foundation Specifications Overall Specifications Measurement range in terms of flow velocity Conbination LF150 LF470 0 1 0 ft s to 0 32 8 ft s 0 0 3 m s to 0 10 m s Fluid conductivity 5µS cm or more Ambient temperature 4 to 140 F 20 to 60 C Storage temper...

Страница 2: ...One point std and three more point is optionally available as follows Digital output DO1 std Output type Transistor open collector Number of outputs One point Output capacity 30Vdc 200mA maximum Digital output DO2 DO4 opt Added when 9th digit of specification code is 3 Out put type Solid state relay output non polarity Number of outputs 3 points Output capacity 150Vdc 150mA maximum or 150Vac peak ...

Страница 3: ... to 60 s selectable in 1s increments Field re verification Mag Prover Toshiba s Zero span calibration tool allows unit to be re calibrated and verified using internal software program For more information contact Toshiba International Corp Conditions when power fails Parameter setting values are stored in non volatile memory and the values will be restored when the power returns to normal conditio...

Страница 4: ... 400 Figure 2 Separate type converter LF232 Excitation cable ground I O cable ground Signal cable ground Grounding terminal Output cable ground Power supply cable ground 2B pipe M10 U bolts In the case of 2B pipe installation 11 to 12 φhole 4 places Installation method Installed by panel or pipe Appointed bout and nut for installation is attached In the case of panel installation Weight Approximat...

Страница 5: ... cable 3 wire hard rubber sheathed cable Digital output Digital output 2 opt Digital output 3 opt Digital output 4 opt Ⅳ wire 5 5mm2 or more Signal cable 2 wire shielded hard rubber sheathed cable Output cable CVV S Power supply CVV Digital I O cable CVV S Thick walled steel conduit Detector Grounded with 100Ω or less ground resistance Grounded with 100Ω or less ground resistance ...

Страница 6: ...Where excessive vibration or mechanical shock occurs Where high temperature or high humidity conditions exist Places where corrosive atmospheres exist Places submerged under water Place where there is sloped floor To put the flowmeter temporarily on the floor place it carefully with something such as stopper to support it so that the flowmeter will not topple over In areas like the following there...

Страница 7: ...munication function HART communication 1 2 Power supply 100Vac 240Vac 50 60Hz Note 2 24Vdc Note 3 A Standard Note 1 For applicable detector code select one from the following table To combine with an existing detector select one depending on the type of replaceable converters For combination with detectors not listed below contact Toshiba Applicable detector code Applicable detector Applicable det...

Страница 8: ...o property or human injury Read related manuals carefully before using this product ISO9001 and ISO14001 are certified Specifications are subject to change without notice Printed in Japan 2008 5 TDOC TOSHIBA Corporation 2008 All Rights Reserved http www toshiba com ind ...

Отзывы: