6
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO281c/351c/451c
SCANNER
6 - 15
4) Original size is determined by the combination of the signals output from each detection point.
Combination charts for size determination of A4 series and LT series are as follows.
[A4 Series]
[LT Series]
* When the platen sensor (S7) is OFF;
• The followings are determined by output signals from the APS sensors.
- Size (The combination of the signals satisfy any in the above chart)
Size is displayed on the control panel and a specific paper or reproduction ratio is selected.
- Size retention (The combination of the signals do not satisfy the above chart)
The latest original size recognized (or no original state) until new paper size is recognized.
- No original (Output from all the sensors are “H”.)
Reproduction ratio and paper are not selected.
• Size change is always observed and detected.
• The carriage-1 stays at the standby position even if the reproduction ratio changes correspond-
ing to the change of the original size.
* When the platen sensor (S7) is ON;
The latest original size (or no original state) recognized right before the platen sensor (S7) is turned
ON is retained regardless of the status the APS sensor output signals.
Size judgement
APS-C
APS-R
APS-1
APS-2
APS-3
A3
0
0
0
0
0
A4
0
1
0
0
0
B4
0
0
0
1
0
B5
1
1
0
1
0
A4-R
0
0
1
1
0
A5
1
1
1
1
0
B5-R
0
0
1
1
1
A5-R
0
1
1
1
1
Size judgement
APS-C
APS-R
APS-2
APS-3
LD
0
0
0
0
LT
0
1
0
0
LG
0
0
1
0
LT-R
0
1
1
0
ST
1
1
1
0
ST-R
0
1
1
1
Code
Output signal
Original
1
H
Not available
0
L
Available
Содержание e-studio281c
Страница 6: ......
Страница 106: ...e STUDIO281c 351c 451c 2005 2008 TOSHIBA TEC CORPORATION All rights reserved COPY PROCESS 3 16 ...
Страница 126: ...e STUDIO281c 351c 451c 2005 2008 TOSHIBA TEC CORPORATION All rights reserved GENERAL OPERATION 4 20 ...
Страница 172: ...e STUDIO281c 351c 451c 2005 2008 TOSHIBA TEC CORPORATION All rights reserved SCANNER 6 28 ...
Страница 182: ...e STUDIO281c 351c 451c 2005 2008 TOSHIBA TEC CORPORATION All rights reserved IMAGE PROCESSING 7 10 ...
Страница 316: ...e STUDIO281c 351c 451c 2005 2008 TOSHIBA TEC CORPORATION All rights reserved REVOLVER UNIT 13 14 ...
Страница 336: ...e STUDIO281c 351c 451c 2005 2008 TOSHIBA TEC CORPORATION All rights reserved TRANSFER UNIT 14 20 ...
Страница 342: ...e STUDIO281c 351c 451c 2005 2008 TOSHIBA TEC CORPORATION All rights reserved IMAGE QUALITY CONTROL 15 6 ...
Страница 398: ...e STUDIO281c 351c 451c 2005 2008 TOSHIBA TEC CORPORATION All rights reserved AUTOMATIC DUPLEXING UNIT ADU 17 20 ...
Страница 408: ...e STUDIO281c 351c 451c 2005 2008 TOSHIBA TEC CORPORATION All rights reserved PC BOARDS 19 2 2 PWA F LGC Fig 19 2 ...
Страница 412: ...e STUDIO281c 351c 451c 2005 2008 TOSHIBA TEC CORPORATION All rights reserved PC BOARDS 19 6 11 PWA F FIL Fig 19 11 ...
Страница 413: ......
Страница 414: ......