System Operation
28
https://www.toshiba.com/tic/
System Operation
Standard Start Up Wizard
Note:
Do not run the Standard Start Up
Wizard and the VLP Wizard. Running
both will result in an operational conflict
that will require a reset to factory
defaults and a restart using only one
wizard. Reset to the factory default
settings after running either wizard to
run the other wizard.
The Start Up Wizard assists with the initial
configuration of the input power settings and the
output parameters of the Q9 Plus ASD.
The Start Up Wizard is launched from Program
Utilities
Standard Start Up Wizard. See the
for more information on
launching the wizard.
The Q9 Plus ASD may also be setup via
communications, by accessing the individual
parameters via the menu hierarchy, or by using the
Direct Access Parameters/Numbers
.
for more information on changing the
parameter settings.
After the initial power up, the wizard may be run on
the next power up operation by setting the following
menu item to Yes — Program
Utilities
Display
Parameters
Display the start up wizard next
power up?
Upon the next power up, the system will launch the
Start Up Wizard. Once completed, the system will
set the Display the start up wizard next power-up?
setting to No (for the next system power up) and
normal start ups will resume.
The Start Up Wizard cannot be used to confirm any
parameter settings. Each time that the wizard is
launched the default settings appear in all write
fields. Any user-written values are recorded and
used by the system. Via direct access, the
individual wizard parameters may be accessed and
viewed to confirm the parameter settings.
The Start Up Wizard
querys the user for the
following information:
1. The
Voltage and Frequency Rating of the Motor
.
4.
continue from step #
).
(
).
).
Volts Per Hertz Control Type (F015)
.
Frequency Command Source (F004)
.
12.The
for current and voltage.
to load the settings of the Start Up Wizard
into the ASD.
See the section titled
for additional information
on the Start Up Wizard.
Operation (Local)
To run the motor perform the following steps:
1. Press the Mode key until the Frequency
Command
screen is displayed.
2. Press the Local/Remote key to enter the Local
mode (Local LED is illuminated).
3. Turn the Rotary Encoder clockwise until the
Frequency Command value is displayed in the
Set
field.
Note:
Ensure that there are no personnel
around or near the motor or the motor-
driven equipment.
4. Press the Run
key (green Run LED illuminates
red) and the motor runs at the Frequency
Command value.
Note:
The speed of the motor may be
changed while the motor is running by
using the Rotary Encoder to change
the Frequency Command value.
5. Press the Stop-Reset key to stop the motor.
Frequency Command Screen.
Содержание DN-68249-003
Страница 1: ...ADJUSTABLE SPEED DRIVES Q9 DN 68249 003 INSTALLATION OPERATION MANUAL April 2020 ...
Страница 2: ......
Страница 3: ...Document Number 68249 003 April 2020 Q9 Plus ASD Installation Operation Manual ...
Страница 4: ......
Страница 12: ...Table of Contents Q9 Plus ASD Install Op Manual iv https www toshiba com tic ...
Страница 305: ......