Direct Access Parameter Information
https://www.toshiba.com/tic/
163
Power Running Torque Limit 1
Program
Torque
Torque Limit Settings
This parameter determines the source of the control signal for the
positive torque limit setting.
is used as the Power
Running Torque Limit 1 input.
Settings:
1 — V/I
2 — RR
3 — RX
4 —
F441 (
Setting)
Direct Access Number —
F440
Parameter Type —
Selection List
Factory Default —
F441 (
Setting)
Changeable During Run —
Yes
Power Running Torque Limit 1 Level
Program
Torque
Torque Limit Settings
This parameter provides a value for the Power Running Torque
Limit 1 setting if
This value provides the positive torque upper limit for the 1 motor.
Direct Access Number —
F441
Parameter Type —
Numerical
Factory Default —
250.00 (Dis
-
abled)
Changeable During Run —
Yes
Minimum — 0.00
Maximum — 250.00 (Disabled)
Units — %
Regenerative Braking Torque Limit 1
Program
Torque
Torque Limit Settings
This parameter determines the source of the Regenerative
Torque Limit control signal.
is used as the Regener
-
ative Torque Limit setting.
Settings:
1 — V/I
2 — RR
3 — RX
4 —
F443 (
Setting)
Direct Access Number —
F442
Parameter Type —
Selection List
Setting
Changeable During Run —
Yes
Regenerative Braking Torque Limit 1 Level
Program
Torque
Torque Limit Settings
This parameter provides a value to be used as the Regeneration
Torque Limit 1 if
.
Set this parameter to 250% to disable this function.
Direct Access Number —
F443
Parameter Type —
Numerical
Factory Default —
250.0 (Dis
-
abled)
Changeable During Run —
Yes
Minimum — 0.0
Maximum — 250.0
Units — %
Содержание DN-68249-003
Страница 1: ...ADJUSTABLE SPEED DRIVES Q9 DN 68249 003 INSTALLATION OPERATION MANUAL April 2020 ...
Страница 2: ......
Страница 3: ...Document Number 68249 003 April 2020 Q9 Plus ASD Installation Operation Manual ...
Страница 4: ......
Страница 12: ...Table of Contents Q9 Plus ASD Install Op Manual iv https www toshiba com tic ...
Страница 305: ......