– 11 –
MMD- AP0214BH2UL, MMD- AP0244BH2UL, MMD- AP0304BH2UL, MMD- AP0364BH2UL
MMD- AP0424BH2UL, MMD- AP0484BH2UL
Air filter slot
5.8"(147.5)
2"(50)
5.2"(131)
1.6"(41)
9.5"(240)
12.6"(320)
6.3"(159.9)
5"(127)
1.7"(42)
Hanging bolt pitch 55.7
±
0.3"(1416)
Unit e
xter
nal dimension 53.2"(1350)
Air discharge flange outside 45.4"(1151.6)
5.5"(140)
1.7"(44)
1.9"(49)
Outside
8.6"(218.2)
Hanging bolt 4-M0.4"(10)
(locally procured)
Unit e
xter
nal dimension 31.5"(800)
Hanging bolt pitch 27.6"(700)
1"(25)
1.6"(41)
2.2"(57)
2.4"(59)
1.2"(30)
15.1"(384)
19.6"(498)
25.1"(638)
2"(50)
Dr
ain pipe connecting por
t
VP25(P
olyvin
yl chlor
ide tube:
Exter
nal Dia,1-1/4" Inter
nal Dia,1"
Air filter slot
z
Refr
iger
ant pipe
connecting por
t Ø5/8"(15.9)
(Gas side)
Ø1"(26) Hole f
or control wire
and remote controller wir
ing
Ø7/8"(22.2) Hole f
or po
w
er supply cab
le
Refr
iger
ant pipe
connecting por
t Ø3/8"(9.5)
(Liquid side)
Air discharge
side
Air intak
e
side
Air intak
e
side
Air discharge
side
Dr
ain-up piping
Air filter slot
Air intak
e flange
9.6"(243.2)
Air intak
e flange outside 50.1"(1271.6)
12.6"(320)
3.6"(91)
6.3"(159)
12"(300) or less
1.2"(30)
10.7"(271)
or less
21.7"(550) or less
2.2"(57)
<Under air intak
e
type>
F
or air intak
e from under air intak
e
, be sure to attach a separ
ately-sold f
an guard.
Model name:TCB-IG211B
UL
Z vie
w
Outside
9.6"(243.2)
Unit width 53.2"(1350)
Ceiling opening siz
e
55.1"(1400)
Air discharge
Electr
ical control bo
x
Air discharge
Electr
ical
control bo
x
Ceiling
Air intak
e
Air filter
(locally procured)
Electr
ical control bo
x
Ceiling
Ceiling opening siz
e
5.9"(150) or more
5.9"(150) or more
Dr
ain pan / Dr
ain
pump chec
k co
v
e
r
*1 In the case of under air intak
e
type
.
:
17.7"(450)(Min.)
Ceiling opening siz
e
Space required f
or installation and ser
vicing
Reser
v
e
space required f
or maintenance the indoor unit and ser
vice w
o
rk
.
38.6"(980)
31.5"(800)
1.2"(30)
5.9"(150)
15.5"(400)
(Min.) *1
4"(100)
4"(100)
Air filter
(locally procured)
Space required f
o
r attaching or
detaching the filter 40.5"(1030)
Space required f
o
r attaching or
detaching the filter 40.5"(1030)
Chec
k por
t A
17.7"X17.7"
(450X450)
Chec
k por
t A
17.7"X17.7"
(450X450)
Notes)
* Set chec
k por
t A f
o
r maintaining the electr
ical control bo
x, filter
, dr
ain pump
, dr
ain pipe
, and refr
iger
ant pipe
.
* Replace the filter through chec
k por
t A or B
.
(If y
ou pull out the filter in the opposite direction of the electr
ical control bo
x, chec
k por
t B is required.)
Reser
v
e
space 40.5"(1030) required f
o
r attaching or detaching the filter
.
Otherwise
, the filter cannot be replaced.
*
When pulling the refr
iger
ant pipe
, dr
ain pipe
, etc
, a
v
oid the filter por
t.
Otherwise
,the filter cannot be replaced.
*
The indoor unit is not equipped with an air filter
. Procure and install with locally
.
* Set a ceiling opening por
t f
or maintaining the f
an, f
an motor
, etc.
Otherwise
, the
y
cannot be maintained.