TOSHIBA
8 - 9
GROUP:FREQUENCY SETTING PARAMETERS
(cont'd)
PARAMETER
DESCRIPTION
LIQUID CRYSTAL DISPLAY
ADJUSTMENT
RANGE
ITEM
NO.
PAGE
NO.
DISPLAY
RESOLUTION
FACTORY
SETTING
Table continued on next page
*Items 99 - 102 are available only when Item 98 Adjustment Range option 1 is selected.
**Items 104 - 107 are available only when Item 103 Adjustment Range option 1 is selected.
***Item 109 is available only when Item 108 Adjustment Range is set to other than "0".
PG TERMINAL STANDARD
98
Bias/gain for PG input selection
0: Standard
-
0
9-14
OR ADJUSTABLE
(option board)
1: Adjustable*
PG REFERENCE SETTING
99*
PG reference point #1
-100 - 100% of Max.
1%
0
9-14
POINT #1
Out. Freq. X PPR
PG REF POINT #1
100*
Output Hz desired when reference
-Max. Out. Freq. to
0.1/0.01 Hz
0.0
9-14
FREQUENCY
equals value entered in Item 99
Max. Out. Freq.
PG REFERENCE SETTING
101*
PG reference point #2
-100 - 100% of Max.
1%
100
9-14
POINT #2
Out. Freq. X PPR
PG REF POINT #2
102*
Output Hz desired when reference
-Max. Out. Freq. to
0.1/0.01 Hz
80.0
9-14
FREQUENCY
equals value entered in Item 101
Max. Out. Freq.
BINARY INPUT STD
103
Bias/gain for binary input
0: Standard
-
0
9-14
OR ADJUSTABLE
(via input terminals).
1: Adjustible**
BINARY REF SETTING
104**
Binary reference point #1
0 - 100 %
1%
0
9-14
POINT #1
BINARY REF POINT #1
105**
Output Hz desired when reference
-Max. Out. Freq. to
0.1/0.01 Hz
0.0
9-14
FREQUENCY
equals value entered in Item 104
Max. Out. Freq.
BINARY REF SETTING
106**
Binary reference point #2
0 - 100 %
1%
100
9-14
POINT #2
BINARY REF POINT #2
107**
Output Hz desired when reference
-Max. Out. Freq. to
0.1/0.01 Hz
80.0
9-14
FREQUENCY
equals value entered in Item 106
Max. Out. Freq.
JOG RUN FREQUENCY
108
Jog run frequency
0.0 - 20***
0.1/0.01 Hz
0.0
9-15
JOG STOP METHOD
109***
Jog stop control
0: Decelerated stop
-
0
9-15
1: Coast to stop
2: DC injection
braking
Содержание Adjustable Speed Drive H3
Страница 1: ...March 2008 Part 46687 004 ...
Страница 2: ......