– 9 –
GENERAL ADJUSTMENTS
SPECIFIC INFORMATIONS
REPLACEMENT OF THE CRT
Service parts are provided for each R, G and B.
The contents of the parts are as follows.
R
G
B
HITACHI
CRT
23008174
23008175
23008176
REPLACEMENT OF HIGH VOLTAGE CABLE
ANODE LEAD
RUBBER BOOT
LEAD HOLDER
Z450 TPA5007
Fig. a
1. When replacing Anode Lead or Anode Cap with new one,
remove Lead Holder from old lead as shown in figure
below, and put it on new lead. Do not throw away Lead
Holder.
NOTE : THE LEAD HOLDER IS ATTACHED TO TPA5007
(Z450), BUT IS NOT ATTACHED TO ANODE
LEAD AND ANODE CAP. RUBBER BOOT IS AT-
TACHED TO ANODE LEAD AND ANODE CAP.
2. Detaching Lead Holder
Fig. b
RUBBER BOOT
OLD
ANODE LEAD
or
ANODE CAP
LOCK
LEAD HOLDER
Cut here rubber boot
and lead together to
detach Lead Holder.
Содержание 51HX93
Страница 24: ... 25 26 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 50: ... 52 SPECIFIC INFORMATIONS THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 51: ... 53 54 SIGNAL BOARD PD1146D BOTTOM FOIL SIDE ...
Страница 52: ... 55 56 DEF CONVER BOARD PD1147D BOTTOM FOIL SIDE ...
Страница 53: ... 57 58 POWER BOARD PD1151C BOTTOM FOIL SIDE ...
Страница 59: ...GEMSTAR BOARD PD1283 TOP FOIL SIDE GEMSTAR BOARD PD1283 BOTTOM FOIL SIDE 65 ...
Страница 61: ... 67 SPECIFIC INFORMATIONS THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 63: ...CIRCUIT BLOCK DIAGRAM 69 70 ...
Страница 65: ...TOSHIBA CORPORATION 1 1 SHIBAURA 1 CHOME MINATO KU TOKYO 105 8001 JAPAN ...