53 / 77
Copyright © 2015 TOSHIBA TELI CORPORATION, All rights reserved.
http://www.toshiba-teli.co.jp/en/index.htm
D4241130B
● Setting
- Set the width of Timer0Active pulse
Set the following value to “TimerDuration” register. Setting value is Float type.
TimerDuration
Pulse width
Minimun (*)
0.00[μs]
Maximum
2000000.00[μs]
* initial factory setting
- Set the delay of Timer0Active pulse
Set the following value to “TimerDelay” register. Setting value is Float type.
TimerDelay
Delay value
Minimun (*)
0.00[μs]
Maximum
2000000.00[μs]
* initial factory setting
- Select the source of Timer0Active pulse to start
Select the foll
owing value to “TimerTriggerSource” register. Setting value is Enumeration type.
TimerTriggerSource
Description
Off
Disables the timer trigger.
Line0Active
Starts when TRIG_IN (Line0) is active.
ExposureStart (*)
Starts with the reception of the Exposure Start
FrameTrigger
Starts with the reception of the Frame Start Trigger.
* initial factory setting
● Note
“TimerTriggerSource” operation is as follows,
Line0Active is available in HardwareTrigger mode, and to be responsed at FrameTriggerError.
FrameTrigger is available in both HardwareTrigger and Software Trigger mode, and not to be responsed at
FrameTriggerError.
ExposureStart is available in both HardwareTrigger and Software Trigger mode, and not to be responsed at
FrameTriggerError. Timer0Active pulse delays TiggTimerDelay[us].