93 / 179
Copyright © 2017 TOSHIBA TELI CORPORATION, All rights reserved.
http://www.toshiba-teli.co.jp/en/
D4267042B
Minimum/Maximum Value
TriggerAdditional
Parameter
Raw Value =
Absolute (Float) Value
Minimum
0
Maximum
255
Initial Value
0
TriggerDelay
Raw Value
Absolute (Float) Value
Minimum
0
0.0 [us]
Maximum
250000000
2000000.0 [us]
Initial Value
0
0.0 [us]
Formula
Absolute Value [us] = Raw Value / 125
● Note
In SoftwareTrigger operation, the delay time from
‘TriggerSoftware’ to exposure is not guaranteed.
DU series and BG series have different hardware trigger source.
Please refer to
‘I/O Specification’ section as well.
TriggerSource
Description
Line0 (*)
I/O connector : 4 pin, High level 2.0 to 24.0V
Line2
I/O connector : 1 pin, High level 4.0 to 5.0V
* initial factory setting
TriggerDelay is applied to both of HardwareTrigger and SoftwareTrigger.
TriggerAdditionalParameter is only effective in Bulk mode.