176 / 179
Copyright © 2017 TOSHIBA TELI CORPORATION, All rights reserved.
http://www.toshiba-teli.co.jp/en/
D4267042B
- MultiFrame function in Random Trigger Shutter mode (TriggerMode = On, TriggerSequence = 0 or 1)
Camera transfers
“AcquisitionFrameCount” frame(s). It
requires
“AcquisitionFrameCount” time(s)
of trigger.
AcquisitionMode = MultiFrame
AcquisitionFrameCount = 3
TriggerMode = On
TriggerSequence = 0 or 1
Trigger
Exposure
Acquisition
Command
Start
Frame 1
Frame 2
Frame 3
Stop
The trigger can be input in arbitrary timing.
Start
Frame 1
Counter is reset.
USB Streaming
Frame 1
Frame 2
Frame 3
Frame 4
Stream
stops
AcquisitionFrameCount
This exposure is
discarded.
Frame 1
*Exposure time is determined by ExposureTime setting in TriggerSequence0.
*Exposure time is determined by the pulse width of the trigger signal in TriggerSequence1.
*Exposure overlaps sensor readout.
- Bulk function (TriggerMode = On, TriggerSequence = 6)
Camera transfers
“TriggerAdditionalParameter” frame(s)
by a single trigger.
Trigger
Exposure
AcquisitionMode = Continuous
TriggerMode = On
TriggerSequence = 6
TriggerAdditionalParameter = 3
Acquisition
Command
Start
Frame 1
Frame 2
Frame 3
*Exposure time is determined by ExposureTime setting.
The trigger can be input in arbitrary timing.
VD
AcquisitionFrameRate
Stop
Start
Frame 1
Counter is reset.
USB Streaming
Frame 1
Frame 2
Frame 3
Frame 1
TriggerAdditionalParameter
Stream
stops
*Exposure overlaps sensor readout.