41 / 172
Copyright © 2019 Toshiba Teli Corpotration, All rights reserved.
http://www.toshiba-teli.co.jp/en/
D4289451A
DeviceControl
Registers of this category provide various information of the camera.
● Registers
Register
Address
GenICam
Interface
Length
Byte / [bit]
Access
Description
DeviceReset
0x20003C
Command
[0]
W
[1] Resets the device.
DeviceVendorName
0x200070
String
16
R
Same as ManufactureName in Bootstrap Registers
DeviceModelName
0x200090
String
16
R
Same as ModelName in Bootstrap Registers
DeviceManufactureInfo
0x2000B0
String
16
R
Same as ManufacturerInfo in Bootstrap Registers
DeviceVersion
0x2000D0
String
16
R
Same as DeviceVersion in Bootstrap Registers
DeviceID
0x200110
String
16
R
Same as SerialNumber in Bootstrap Registers
● Note
-
DeviceReset
Camera executes the USB Bus reset operation by DeviceReset command.
- Plug-and-play happens, camera handles used in the application become invalid.
- The application is required to close and re-open the camera.