D4134051A 

 
BEFORE USE - GENERAL SAFETY INSTRUCTIONS 

This specifications contains important information for the operator (user) and/or people in the 

vicinity to avoid personal injury, or property damage.   

 

Prior to use, read this specifications carefully to fully understand its instructions for correct use. 

 

After reading, keep operation manual near the equipment for future reference. 

 

WARNINGS & CAUTIONS 

Indication 

Meaning 

WARNING 

This indicates the existence of a hazard that death or catastrophic bodily 

injury(*1) may result from improper use. 

CAUTION 

This indicates the existence of a hazard that bodily injury(*2) or property 

damage(*3) may result from improper use. 

Notes

 

*1 Catastrophic bodily injury means loss of eyesight, burns (high and low temperatured), shock, 

fracture, poisoning, etc. which leaves a sequela and repuire hospitalization or prolonged 

treatment. 

*2 Bodily injury means injuries, burns and electric shock which does not require hospitalization 

or prolonged treatment. 

*3 Property damage means extended harm to home, household effects, domesticated animals, and 

pets. 

 

Graphic symbol definitions 

Indication

 

Meaning

 

    

This mark indicates a prohibited action that must not be carried out. The actual 

prohibited action is indicated in the symbol or nearby graphically or described in 

text.

 

    

This mark indicates a mandatory action that must not be carried out. The actual 

instruction is indicated in the symbol or nearby graphically or described in text. 

 

Handling Precautions

 

 

  

 

 

  

 

WARNING 

 

Stop operation immediately when any abnormality or defect occurs. 

Use during an abnormal condition; such as emitting smoke, burning odors, 

damage from dropping invasion of foreign objects, etc. may cause fire and/or 

electric shock. Be always sure to disconnect the power plug from the electrical 

outlet (socket) at once and contact your dealer.

 

  

Do not operate in places with possibility of becoming wet. 

This may cause fire and/or electric shock. 

Important Safety Precautions 

Содержание CS3910BH

Страница 1: ...134051A High Resolution CCD Camera Model CS3910BH Specifications Contents 1 PRODUCT DESCRIPTION 6 2 FEATURES 6 3 COMPONENTS 6 4 FUNCTION 7 5 SPECIFICATIONS 12 6 TIMING CHART 15 7 EXTERNAL VIEW DRAWINGS 18 ...

Страница 2: ...means injuries burns and electric shock which does not require hospitalization or prolonged treatment 3 Property damage means extended harm to home household effects domesticated animals and pets Graphic symbol definitions Indication Meaning This mark indicates a prohibited action that must not be carried out The actual prohibited action is indicated in the symbol or nearby graphically or describe...

Страница 3: ...le Otherwise fire or electric shock may result CAUTION Note the following instructions when installing Do not wrap the product in an inflammable material such as cloth Do not put the product in a narrow space since the heat generated from the product may be difficult to emanate If you do not follow the above the heat generated by the product may cause fire Avoid setting in humid smoky vaporized or...

Страница 4: ...all be held harmless for any damages or losses incurred by the user in any of the following cases Fire earthquake or any other act of God acts by third parties misuse by the user whether intentional or accidental use under extreme operating conditions Malfunction or non function resulting in indirect additional or consequential damages including but not limited to loss of expected income and suspe...

Страница 5: ...ormance and safety of the equipment or devices This product is not designed or manufactured to be used for control of equipment directly concerned with human life 1 or equipment relating to maintenance of of public services functions involving factors of safety 2 Therefore the product shall not be used for such applications 1 Equipment directly concerned with human life refers to Medical equipment...

Страница 6: ...nse light Avoid intense light such as spot light on part of the screen because it may cause blooming or smears If intense light falls on the screen vertical stripes may appear on the screen but this is not a malfunction Do not expose the camera s image pickup plane to sunlight or other intense light directly Its inner CCD charge coupled device might be damaged Moire When thin stripe patterns are s...

Страница 7: ...eed is selectable among 8 scales from 1 30s through 1 10000s 5 Digital Output Digital format output EIA 644 single channel 10 bit is available 6 External sync Operation Upon receiving external HD VD IN the camera automatically switches into ex sync operation 7 All pixel read out mode Normal mode This model can readout all pixel data effective area in 1 15 second 8 High speed draft mode The High sp...

Страница 8: ...tical 2 lines in 8 lines read out at the same timing under this mode vertical resolution is reduced to 1 4 SW1 2 ON OFF ON OFF SW1 3 OFF ON Random Trigger Shtter Multiple shutter FIX mode Shutter OFF Nomal Shutter Random Trigger Shtter Multiple shutter pulse mode Mode Function Rear panel DIP switches 1 1 Partial scan SW1 5 Draft 2 AGC SW1 1 OFF OFF OFF ON ON ON ON OFF SW2 Inner SW 1 2 3 4 5 6 DRAF...

Страница 9: ... 4000 ON ON ON 1 10000 3 External sync setting HD VD a SW1 Function indication Switch selection Function selection DATA DATA OUT CONNECTOR External sync connector selection DATA DCIN DCIN DC IN SYNC CONNECTOR b SW2 Function indication Switch selection Function selection IN Input External sync input output selection IN OUT OUT Output HD VD connector selection PROCESS TIMING CPU REG SW1 HD VD IN OUT...

Страница 10: ...ulse length longer than 1H Approximately 62 5 micro s After video output it goes back into normal operation inner DIP switches if the TRIG terminal voltage stays in LOW The exposure starts at the next HD timing immediately after TRIG IN Video output timing 1 Fix mode The VD is output in sync with the next HD after light exposure 2 Pulse mode The VD is output in sync with the next HD after light ex...

Страница 11: ...on shutter OFF if the TRIG terminal voltage stays in LOW for 2V or longer consecutively regardless of which RTS mode is currently set in 1 Fix mode 1 Pulse mode A B A B 20μs 20μs Exposure time Setting with TRIG pulse interval approx 15 micros TRIG CCD Exposure E VD VIDEO OUT HD WEN VD approx 5micros approx 5micros Exposure time Setting with TRIG pulse interval approx 15 micros A B A Exposure time ...

Страница 12: ...er read out Opening pixel 271line Opening pixel 487line Opening pixel 280line Normal speed Transfer High speed Transfer VIDEO OUT Normal VIDEO OUT High speed Transfer Normal speed Transfer Center1 2 Scan Range 523 line High speed Transfer 14line Normal speed Transfer 487line Total 523line approx 32 3Hz Empty Transfer BLK 2line High speed Transfer High speed Transfer Empty Transfer BLK 2line High s...

Страница 13: ... from 1 30s through 1 10000s RTS Random Trigger Shutter ON OFF selectable factory setting OFF Fix mode Exposure time determined by E shutter speed Pulse mode Exposure time determined by pulse width Partial scan ON OFF selectable factory setting OFF ON Screen center 1 2 readout Multiple shutter ON OFF selectable factory setting OFF Fix mode Exposure time determined by E shutter speed Pulse mode Exp...

Страница 14: ...hm CLOCK Output from DATA OUT EIA RS644 LVDS Driver output voltage 350mV Differential output 100 ohm Mechanical dimensions 1 Lens mount C mount 2 External dimension 49 W x 35 H x 98 D mm 3 Weight Approx 170g 4 Chassis GND Isolation Conduct from circuit GND and Chassis Combination of C mount lens As for the C mount lens used combining this camera the projection distance from bottom of the screw sho...

Страница 15: ...ignal name 1 DATA0 H 10 DATA4 L 19 DATA9 H 28 E HD IN 2 DATA0 L 11 DATA5 H 20 DATA9 L 29 E VD IN 3 DATA1 H 12 DATA5 L 21 VD OUT H 30 N C 4 DATA1 L 13 DATA6 H 22 VD OUT L 31 BUSY 5 DATA2 H 14 DATA6 L 23 HD OUT H 32 WEN 6 DATA2 L 15 DATA7 H 24 HD OUT L 33 N C 7 DATA3 H 16 DATA7 L 25 CLK H 34 N C 8 DATA3 L 17 DATA8 H 26 CLK L 35 GND 9 DATA4 H 18 DATA8 L 27 TRIG IN 36 GND DATA0 LSB DATA9 MSB Pin numbe...

Страница 16: ...tput voltage Plus minus 350mV Differential output 100 ohm H Rate Total clock counts 1790CLK 1H DATA counts 1392CLK 1H CLK 34 92ns V rate phase Same as one in analog timing chart V Rate A 3H B 3H C 6H D 1040H E 1046H CLK DATA HD 276CLK 1392CLK 1790CLK 17 5ns 122CLK C D E DATA VD A B ...

Страница 17: ...All pixels read out HD VD WEN SG VD 1 15Hz 65 4ms 1046H Pulse width Longer than 1H E VD Phase lag 200ns or less against HD E HD HD VD DATA WEN CCD Exposure 1046H 15 29Hz Exposure time setting with inner DIP SW 1 2 3 4 5 6 1038 1039 1040 7 DATA VD HD WEN 8 ...

Страница 18: ...17 D4134051A 60Hz High speed draft read out 1 4 9 12 17 20 1028 1033 1036 25 DATA VD HD WEN 28 33 HD VD DATA WEN CCD Exposure 262H 60 37Hz Exposure time setting with inner DIP SW ...

Страница 19: ...18 D4134051A 7 EXTERNAL VIEW DRAWING ...

Отзывы: