Rev 3.0
D4161841C
21
10. Before determining it as being a fault
If any trouble occurs in use, check the following first.
If the trouble persists, contact your distributor or our sales representatives.
Phenomena
Check item
Cannot turn on power
- Check the connection of the camera adapter and power cable.
Shooting image is not displayed
- Check the connection of the camera link cable and camera cable.
- Check that the camera register settings are correct.
- Check that the dip switch settings are correct.
- Check that lens aperture is not closed.
- Check that the grabber board is installed and set up correctly.
Frame drop occurs on shooting
image
- In the PCI bus system, a frame dropping may occur because the
transfer rate is too slow for the amount of data to be transferred. Ensure
that no frame dropping occurs with a grabber board and PC for PCI
Express x4.
- If more than one boards are installed in the PCI slots, remove the other
boards.
Shooting image remains still
- Check that the camera is not in the random trigger mode.
- Check the setting of the grabber board.
- Check the connection of the camera link cable.
Cannot control camera from PC
- Check the connection of the camera link cable.
- Check the dip switch setting (communication speed setting).
- Check that the grabber board is installed and set up correctly.