2 | 

P a g e

 

 

13.

 

Do not position the equipment so that it is difficult to operate the disconnecting device (power cord).

 

14.

 

If the equipment is used in a manner not specified by the manufacturer, the protection provided by 

the equipment may be impaired.

 

15.

 

The power switch should be in the “off” position when connecting or disconnecting equipment from 

a Torus Power unit.

 

16.

 

CAUTION Some units can be very heavy, please use safe practices when lifting.

 

 

 

Содержание AVR2 ELITE 16 520R

Страница 1: ...AVR2 ELITE Series Owner s Manual O...

Страница 2: ...re eliminated through the toroidal isolation transformer using patented Narrow Bandwidth Technology The toroidal isolation transformer provides high levels of instantaneous current making sure even dy...

Страница 3: ...9 USB 2 0 Port 9 12VDC Trigger On Off 9 12VDC Fault Output 9 Circuit Schematics 10 AVR ELITE Embedded Software 12 Username and Password 12 AVR ELITE Menu Selections 13 Torus Power Connect 21 User Reg...

Страница 4: ...of fatal shock 6 Ventilation The device should always be located in such a way that it maintains proper ventilation It should never be placed in a built in installation or anywhere that may impedethe...

Страница 5: ...he equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired 15 The power switch should be in the off position when connecting or disconn...

Страница 6: ...s not insurable by carriers otherwise Placement Ventilation Torus Power PIUs Power Isolation Units are extremely efficient yet very high power devices and must be adequately cooled PIUs have ventilati...

Страница 7: ...ss components and shorten equipment life with worst case catastrophic events destroying valuable equipment In such real world conditions the Torus Power AVR ELITE can protect your equipment and improv...

Страница 8: ...time you push the button the display will show a different feature of the AVR ELITE When you first turn on the AVR ELITE the System Status will appear Each time you push the button it will change from...

Страница 9: ...1 minute consecutively the AVR ELITE will resume normal operation and the High or Low AC Voltage advisory message will no longer appear on the LCD display The rear panel outlet zones will provide powe...

Страница 10: ...5V to 90V and between 130V and 135V the regulation will be reduced 4 North American BAL models Torus AVR ELITE will keep the output constant within the rangeof 120 4V with an input voltage of 180V to...

Страница 11: ...elect the order in which your components are switched on For example components that should be switched on first such as front end components can be connected to Zone A and Zone B Components to be swi...

Страница 12: ...ON the AVR ELITE and removing the 12 volts turns it OFF Requires a 3 5 mm TS type male audio connector with tip wired as positive and sleeve wired as negative from controlling source 12VDC Fault Outpu...

Страница 13: ...10 P a g e Circuit Schematics North American Model AVR2 ELITE 20...

Страница 14: ...11 P a g e North American Model AVR2 ELITE 40 BAL International Model AVR2 ELITE 16 CE...

Страница 15: ...n 2 Use a three way DHCP Router You then connect both PC and AVR ELITE to the same DHCP Router Open a browser window from the PC Type AVR or the IP address displayed on the LCD into the browser window...

Страница 16: ...ctioning normally or whether there is a fault condition No password required to monitor status Switch Main Power This screen allows ON OFF control of the AVR ELITE unit Press the SET button to impleme...

Страница 17: ...er entering the configuration parameters use the Send Test Email button to confirm your settings are correct Date and Time Setup When the AVR ELITE is connected to the Internet the date time and day w...

Страница 18: ...et Zone R will act like a regular zone and can be programmed to switch ON OFFindividually like other zones see page 8 Zone Power Control Zone R works with the Schedule Manager and can be programmed to...

Страница 19: ...Each AVR ELITE unit has a unique MAC Address which is factory assigned The IP address assigned to the AVR ELITE is dynamically assigned and is displayed on this screen as well as on the front panel LC...

Страница 20: ...x 45A 90A 7 R Mechanical Specifications Model Number Input Connector Rear Panel Output Connector Rear Panel Line Cord Size mm WxDxH Size inch WxDxH Weight KG lb Chassis Height AVR2 ELITE 20 IEC 20A In...

Страница 21: ...R AVR2 ELITE 30 520R 2 x 30A Fuses 30A 7 R Mechanical Specifications Model Number Input Connector Rear Panel Output Connector Rear Panel Line Cord Size mm WxDxH Size inch WxDxH Weight KG lb Chassis H...

Страница 22: ...0VAC 2 5M Plug BS 1363 Connector IEC C19 483x559x249 17x22x9 8 56 5 125 5U 8 75 AVR2 ELITE 30 AUS Hubbell Twist lock 30A 250V NEMA L6 30P 20A 250V AUS Socket x8 Twist lock 2 5M 10AWG 30A 86 190 AVR2 E...

Страница 23: ...on switch for approximately 30 seconds and then release the pushbutton switch 5 Use the pushbutton as you would normally to scroll through the various screens until you get to the IP address screen an...

Страница 24: ...orus Power Connect provides Users with a custom dashboard for control status setup and configuration purposes One year of Torus Power Connect service is included with each new AVR Elite purchase A sub...

Страница 25: ...t directly 1 877 337 9480 Dealer Installer Registration Your Torus Power dealer installer will get the required details to proceed with the registration and activation of this service for your AVR Eli...

Страница 26: ...vailable options Highlight and click to select the desired option see below for details of each option System Status Click the Show text for a specific AVR Elite device to view its system status detai...

Страница 27: ...or a specific AVR Elite device to easily view its input voltage output voltage input current output current and output Total Harmonic Distortion values Clicking the Refresh text bar will update the Li...

Страница 28: ...he Control text for a specific AVR Elite device to manually control ON OFF the unit s power state or the power state of each individual outlet zone Click the Refresh Reported Values text to confirm th...

Страница 29: ...d be cycled if the initial power cycle failed to restore internet connectivity This power cycle will be attempted a maximum of three time This setting requires the Zone R Router Reset box to be checke...

Страница 30: ...27 P a g e...

Страница 31: ...28 P a g e Historical Charts Click the Plot text for a specific AVR Elite device to Move the mouse cursor to one of the plot points to get the value and time for that data point...

Страница 32: ...29 P a g e...

Страница 33: ...t data values and the Requested Interval is the time period duration to be provided The data is listed chronologically in one minute intervals as the default sort order The data can be sorted by the v...

Страница 34: ...31 P a g e...

Страница 35: ...create a scheduled power on or off click the desired day then type in the hour and minutes 24 hour format or use the up down arrows to scroll to the desired value Check the box associated with each zo...

Страница 36: ...33 P a g e...

Страница 37: ...file or a fixed format pdf file The CSV format file can be imported into a spreadsheet software program such as Microsoft Excel so it can be manipulated to filter present the information in the desir...

Страница 38: ...e Personal Information home screen shows the User s contact information submitted during the Torus Power Connect registration The User can use the Change Password text bar at any time to submit a new...