North American Model Numbers

19” Pro Series

Rack Mount(RM)

AVR 15 RK

AVR 20 RK

AVR 20 BAL RK

Description

Single 15A

Single 20A

Balanced 20A

Input

(Nominal)

120V

120V

240V

Output

Connector

10 outlets

Medical-grade

15A

10 outlets

Medical-grade

20A

10 outlets

Medical-grade

20A

17” Consumer

Series (CS)

AVR 15 CS

AVR 15 CB

AVR 20 CS

AVR 20 CB

AVR 20 BAL CS

AVR 20 BAL CB

International Model Numbers

19” Pro Series

Rack Mount(RM)

AVR 4 UK RK

AVR 4 CE RK

AVR 4 AUS RK

AVR 8 UK RK

AVR 8 CE RK

AVR 8 AUS RK

AVR 16 UK RK

AVR 16 CE RK

AVR 16 AUS RK

Description

International 4A

United Kingdom

International 4A

Continental Europe

International 4A

Australian

International 8A

United Kingdom

International 8A

Continental Europe

International 8A

Australian

International 16A

United Kingdom

International 16A

Continental Europe

International 16A

Australian

Input

(Nominal)

230V

230V

240V

230V

230V

240V

230V

230V

240V

Output

Connector

3 outlets

UK panel mount

socket

4 outlets 16A/250V

Ivory Continental

European Socket

3 outlets

Australian

Interpower Socket

5 outlets

UK panel mount

socket

5 outlets 16A/250V

Ivory Continental

European Socket

5 outlets

Australian

Interpower Socket

6 outlets

UK panel mount

socket

8 outlets 16A/250V

Ivory Continental

European Socket

5 outlets

Australian

Interpower Socket

17” Consumer Series

(CS)

AVR 4 UK CS

AVR 4 UK CB

AVR 4 CE CS

AVR 4 CE CB

AVR 4 AUS CS

AVR 4 AUS CB

AVR 8 UK CS

AVR 8 UK CB

AVR 8 CE CS

AVR 8 CE CB

AVR 8 AUS CS

AVR 8 AUS CB

AVR 16 UK CS

AVR 16 UK CB

AVR 16 CE CS

AVR 16 CE CB

AVR 16 AUS CS

AVR 16 AUS CB

Page 11

Output

(Nominal)

120V

120V

120V

*Note: For the Nominal Output Voltages of the International models please see table at the top of

page 9 under Block Diagram - AVR System.

www.TorusPower.com

Owner’s Manual

AVR

Audio / Video Power Isolation Units

Rack Mount (RK) / Consumer (C)

04/12

Power Conditioners

REV.04/19/2012

Содержание AVR 15 CB

Страница 1: ...s Manual Audio Video Power Isolation Units with Automatic Voltage Regulation 19 Pro Series Rack Mount RK Faceplate 17 Consumer Series C Faceplate Available in Black B and Silver S Colours Isolate Protect Inspire ...

Страница 2: ... American Models Line Cords and Wall Receptacles for North American Models Rear Panel Layout of North American Models Electrical Specifications International Models Mechanical Specifications International Models Page 1 Page 3 Page 4 Page 5 Page 6 7 8 Page 9 Page 10 Page 10 Page 11 Page 11 Page 12 Page 12 Page 12 Page 13 Page 13 Page 14 Page 14 Page 1 Rear Panel Layout of International Models Page ...

Страница 3: ...ver be placed in a built in installation or anywhere that may impede the flow of air through its ventilation slots 7 Heat Never locate the device near heat sources such as radiators floor registers stoves or other heat generating devices 8 Power Cord Protection Power cables should be routed so they are not likely to be stepped on or crushed by items placed on them or against them Special attention...

Страница 4: ...for any input voltage from 90V to 130VAC International units operate within nominal input voltage such as 220V 230V 240V Torus AVR keeps them operating within a range of 10V See table on Page 9 for more details Torus Power AVR series uses a micro processor to monitor and control the power provided to connected components The front panel display on the Torus Power AVR indicates input and output vol...

Страница 5: ...Front Panel Display Page 4 If ethernet connection is used www TorusPower com Owner s Manual AVR Audio Video Power Isolation Units Rack Mount RK Consumer C 04 12 Power Conditioners REV 04 19 2012 ...

Страница 6: ... to the Ethernet port Open a browser window on a PC that is connected to the same network through another Ethernet port Enter AVR or the I P address displayed on the LCD into the browser window Press ENTER and the software will open 2 Use a three way Hub which is connected to an existing network You then connect both PC and AVR to the same Hub Open a browser window from the PC Type AVR or the I P ...

Страница 7: ... Default Password avr You can change your password Select Set Password AVR Status This screen indicates the overall status of the system showing Voltage In Voltage Out and Current output It also reports if the system is functioning normally or whether there is a fault condition AVR Power Control This screen allows ON or OFF control of the AVR unit Press SET button to implement your selection www T...

Страница 8: ...ions press SAVE SETUP Email Fault Alert Notification In the unlikely event your AVR experiences an issue the AVR will shut down and send an email notification if this section is configured After entering the configuration parameters use the Send Test Email button to confirm your settings are correct Set Password If you wish to change the password use this screen In case your forget your new passwo...

Страница 9: ...us AVR will keep the output constant within the range of 115Volts to 125Volts with an input voltage of 170V to 270V Between 160V to 170V and between 260V and 270V the regulation will be reduced 5 International models 4A 8A and 16A Torus AVR will keep the output constant within the range of 240 10Volts with an input voltage of 170V to 270V Between 160V to 170V and between 260V and 270V the regulati...

Страница 10: ...oard Power ON OFF Switch Circuit Breaker IEC Inlet Medical Grade Outlets Input 240V Output 120V 3 0A www TorusPower com Owner s Manual AVR Audio Video Power Isolation Units Rack Mount RK Consumer C 04 12 Power Conditioners Potential Transformer 2 7 7 Available Models Model Nominal Input Operable Input Range Output North American 120V 85V 135V 120V 5V International 220V 150V 250V 220V 10V Internati...

Страница 11: ...r reference only Torus Power AVR units have no serviceable parts inside Please return unit to manufacturer for repair and service when required Page 10 INPUT 120VAC www TorusPower com Owner s Manual AVR Audio Video Power Isolation Units Rack Mount RK Consumer C 04 12 Power Conditioners REV 04 19 2012 ...

Страница 12: ...16A Australian Input Nominal 230V 230V 240V 230V 230V 240V 230V 230V 240V Output Connector 3 outlets UK panel mount socket 4 outlets 16A 250V Ivory Continental European Socket 3 outlets Australian Interpower Socket 5 outlets UK panel mount socket 5 outlets 16A 250V Ivory Continental European Socket 5 outlets Australian Interpower Socket 6 outlets UK panel mount socket 8 outlets 16A 250V Ivory Cont...

Страница 13: ... 5lbs 45 0kg 99lbs 45 7kg 100 5lbs 45 0kg 99lbs 20 9kg 46lbs 20 2kg 44 5lbs Size mm Size inch w x d x h 483 x 565 x 159 19 x 22 25 x 6 25 432 x 556 x 162 17 x 22 x 6 4 483 x 565 x 159 19 x 22 25 x 6 25 432 x 556 x 162 17 x 22 x 6 4 483 x 489 x 102 19 x 19 25 x 4 432 x 480 x 105 17 x 18 9 x 4 13 Height includes rubber mounting feet The front panel power switch is also a circuit breaker As a circuit...

Страница 14: ...2 pole 3 wire grounding 15A 250V 3 x 14AWG 2 5 m 20 BAL CS and AVR 20 BAL CB Standard 20A 120V Used on Equipment end Plug Cord Length Model Number AVR 20 RK AVR IEC C19 5 20P Straight Blade 2 pole 3 wire grounding 20A 125V 3 x 12AWG 2 5 m 20 CS and AVR 20 CB Standard 15A 120V Used on Equipment end Plug Cord Length IEC C13 5 15P Straight Blade 2 pole 3 wire grounding 15A 125V 3 x 14AWG 2 5 m Model ...

Страница 15: ...CB AVR 16 CE CS AVR 8 CE RK AVR 8 CE CB AVR 8 CE CS AVR 4 CE RK AVR 4 CE CB AVR 4 CE CS AVR 16 AUS RK AVR 16 AUS CB AVR 16 AUS CS AVR 8 AUS RK AVR 8 AUS CB AVR 8 AUS CS AVR 4 AUS RK AVR 4 AUS CB AVR 4 AUS CS Electrical Specifications International Models Input Voltage Nominal 2 0VAC 3 Range 10 voltage 47 53Hz 230VAC Range 10 voltage 47 53Hz 240VAC Range 10 voltage 47 53Hz Model Number AVR 16 UK RK...

Страница 16: ...nental Europe CE AVR 4 CE C AVR 4 CE C 4A Model Numbers AVR 4 RK S and B United Kingdom 4A Model Numbers AVR 4 UK RK S and B AVR 4 UK C AVR 4 UK C Australian 16A Model Number AVR 16 AUS RK S and B AVR 16 AUS C AVR 16 AUS C Continental Europe CE AVR 16 CE C AVR 16 CE C 16A Model Number AVR 16 RK S and B United Kingdom 16A Model Number AVR 16 UK RK S and B AVR 16 UK C AVR 16 UK C 10A 250V Interpower...

Страница 17: ...age is extended to applicable products registered or having proof of purchase sales invoice etc In the event of a defect or malfunction Torus Power will remedy the problem by repair or replacement as we deem necessary to restore the product to full performance This warranty is considered void if the defect malfunction or failure of the product or any component part was caused by damage not resulti...

Страница 18: ...gnetic Drive Toronto ON M3J 3J2 Canada 416 667 9914 Torus Power products are marketed worldwide through Plitron Manufacturing Inc Phone 416 667 9914 Toll free 1 800 754 8766 Fax 416 667 8928 For sales contact torussales plitron com Technical inquiries torustechnical plitron com Phone 416 667 9914 REV 04 19 2012 ...

Отзывы: