Hydraulic Motor Case Over-Pressure Protection  

Hydraulic motor case over-pressure relief protection is standard on Torrent mulching 
attachments. If for any reason the case drain circuit become restricted due to a pinched case 
drain hose, blocked due to a disconnected coupling or failure to open an isolation valve, or 
exposed to excessive pressure due to improper installation, the motor shaft seal and casing 
are protected from damage by a low pressure relief valve connected to the motor casing. 
Should pressure in the motor case exceed 55 psi (3.6 bar), hydraulic oil is vented through the 
case over-pressure relief valve discharging to atmosphere through a port visible to the 
operator. Should oil be observed issuing from the case over pressure vent, the unit must be 
shut down and the cause of the over pressure be identified and corrected. Oil issuing from 
the vent while the excavator is running while the mulching pressure circuit is turned off 
indicates the pressure is being applied to the case drain circuit by the excavator and 
indicates that the case drain circuit has been connected to main return or at a point where 
system back pressure is present.   

 

Hose Routing 

Hydraulic hoses must be routed in such a way as to prevent pinch points or excessive strain 
or tension. Once all three hydraulic hoses are connected between the mulcher and the 
boom of the excavator it is important to slowly extend/retract the bucket curl function from 
full curl out to stop and then full curl in to stop making certain that the hoses are clear of 
pinch points, abrasion or excessive tension. Hoses that are too long when bucket curl out to 
stop is reached are susceptible to being caught or torn off during mulching operations, the 
vast majority of which is conducted while the mulching drum is parallel to the ground. A 
typical routing of the mulcher hose group can be seen in figures # xxxxx 

 

 

Содержание 30" SHARK

Страница 1: ...30 SHARK Owner s Manual...

Страница 2: ...ule 7 Lubrication 8 30 SHARK Technical Specifications 9 Preventive Maintenance Instructions 10 DAILY 10 WEEKLY Every 50 Hours of Operation 14 MONTHLY Every 200 Hours of Operation Error Bookmark not de...

Страница 3: ...of the Equipment and RWI shall at its expense return the Equipment to Customer in the same or equivalent manner that the Equipment was delivered to RWI Part s replaced during this Limited Hardware Wa...

Страница 4: ...lcher the carrier other property or injury or death of operation personnel or pedestrians This unit must not be used within 100 meters of objects other machinery livestock pedestrians or personnel oth...

Страница 5: ...cal personnel only RWI Ltd accepts no responsibility for damage or injury resulting from inadequate or improper installation of its products WARNING When servicing cutters the cutting drum must be mec...

Страница 6: ...vestock and roadways are greater than 100 meters from where the mulching equipment is being operated The operator must always remain inside the operator s compartment while the mulcher drum is turning...

Страница 7: ...mulching head horizontal toward the right side of the tree 2 Using the left or discharge side of the mulching drum slowly cut into the right portion of the treetop being careful not to cut the top of...

Страница 8: ...ng bearing grease 1 shot each x Lubricate drive coupling with multipurpose EP grease 2 shots x Inspect cutters for excessive wear or breakage x Inspect tool Holders for excessive wear or damage x Insp...

Страница 9: ...ct specification and inadequate application of the lubricant Use of FAG Arcanol Multitop Rolling Bearing Lubricant is recommended for use in the lubrication of all Torrent Shark series drum shaft bear...

Страница 10: ...nimum 3200 max continuous Carrier power requirement 40 Hp or 28 Kw minimum Cutter type Fixed round or square Cutter quantity 24 Drive type Direct Power transmission type Hydraulic fluid power Hydrauli...

Страница 11: ...ks or Damage The hydraulic hose assemblies connecting the mulching unit to the boom of the carrier are exposed to impact and abrasion as a normal course of operation Hydraulic hoses and fittings must...

Страница 12: ...Lubricate main shaft bearings twice daily with one shots of special purpose grease suitable for operating conditions see Recommended Rolling Bearing Lubricant Specifications for lubricant requirement...

Страница 13: ...quarely on the ground or other flat solid surface and with the carrier in a ZERO ENERGY STATE apply two shots of multipurpose ie Pin and bushing grease to the grease fitting into the side of the cutti...

Страница 14: ...d lock washer 2 Turn 90 degrees or as required to expose a new cutting edge if no new edges remain replace the cutter with a new one 3 Torque to 75 Nm Do not use an impact wrench to tighten the cutter...

Страница 15: ...up and down may indicate worn or damaged bearings Excessive endplay may be detected by placing a pry bar between the cutting frame and either end of the cutting drum A small amount of end play approx...

Страница 16: ...l procedures to be carried out on the 30 SHARK must be performed with the unit resting squarely on the ground or other flat solid surface and with the carrier in a ZERO ENERGY STATE The 30 SHARK is a...

Страница 17: ...gned with an 8 bolt pattern for the purpose of anchoring a quick coupler to match that of recipient excavator The dimensions of the deck plate and the bolting pattern are supplied in the following dia...

Страница 18: ...30 SHARK Owner s Manual 17...

Страница 19: ...ing the rotor from dead stop to full speed The minimum recommended pressure supply line size is 19mm inside diameter and capable of withstanding pressure established by the circuit relief setting Main...

Страница 20: ...30 SHARK Owner s Manual 19...

Страница 21: ...draulic motor when the mulching drum typically rotating at over 3000 rpm contacts hard immoveable objects that are often not visible to the operator Case Drain Pressure Gauge A pressure gauge and T as...

Страница 22: ...and corrected Oil issuing from the vent while the excavator is running while the mulching pressure circuit is turned off indicates the pressure is being applied to the case drain circuit by the excava...

Страница 23: ...sed to a standing level of water snow etc Covers should be removed and the unit drained of any accumulated water hoses should be capped or covered to prevent corrosion or contamination and preservatio...

Страница 24: ...tter 3005492 Cutter Hex Bolt x 1 UNF Grade 8 c w High Collar Lock Washer 3005493 Drum Shaft 3004001 Power Lock Coupling 3004001 Flanged Cartridge Bearing Assembly Idler 3004003 Flanged Cartridge Beari...

Страница 25: ...30 SHARK Owner s Manual 24...

Страница 26: ...30 SHARK Owner s Manual 25...

Отзывы: