© Sensor Technology Ltd 2016 ORT4019R (Preliminary) Feb 2016
ORT 230/240 Series Torque Transducers - Standard Range
● – Standard feature ◊ – Optional feature
ORT 230/240
Series
Option
Code
Remarks
Torque, Speed, Power Outputs
ORT 230
ORT 240
Torque only
230
240
Torque & Speed
(60 pulses/rev)
231
User to specify RPM/FSD
when ordering
Torque & Power
(60 pulses/rev)
233
User to specify Power/FSD
when ordering
Torque & Speed
(60 pulses/rev)
or Power
241
Outputs are user selectable
Standard features
Voltage output ±5v FSD (Fixed)
●
B
Voltage outputs from ±1v to ±10v FSD
and unipolar (Variable)
●
Output is user selectable
RS232 output
●
Torque Averaging & Torque Peak
●
Self Diagnostics
●
●
Internal temperature measurement
●
●
Value available on ORT240
series only
Deep grooved shielded bearings with oil
lubrication
●
●
Ingress Protection (IP) 54
●
●
Link Cable (1.5m)
●
●
From sensor head to
electronics module
Optional features
Keyed Shaft Ends
●
●
K
1Nm flats, below 1Nm plain
Plain Shaft Ends
◊
◊
P
Shaft length may be longer
than keyed end shafts –
consult factory for length.
All sensors below 1Nm will
be plain.
Splined Shaft Ends
◊
◊
T
Consult factory for details
Voltage output ±1v FSD (Fixed)
◊
A
In place of Option B
Voltage output ±10v FSD (Fixed)
◊
C
In place of Option B
Customer Specified Voltage Output
(Fixed)
◊
U
In place of Option B. User
to specify range/scale when
ordering
Current output 0-20mA (Fixed)
◊
D
In place of Voltage output
options
Current output 4-20mA (Fixed)
◊
E
In place of Voltage output
options
Current output 12±8mA (Fixed)
◊
V
In place of Voltage output
options
Current output 0-20mA, 4-20mA
& 12±8mA (Variable)
◊
F
Current output is user
selectable and in place of
Voltage output. However
user can reselect a Voltage
output, if required. (Note 6)
USB2.0 full speed 12 Mbps Digital output
◊
G
CANbus output
◊
H
In place of RS232
High Speed Bearings
(See Note 7 below)
◊
◊
J
Sealed Bearings
◊
◊
S
Ingress Protection (IP) 65 –for sensor
and electronics
(See Note 8 below)
◊
◊
L
Consult factory for maximum
speed allowance
Link Cable (>1.5m)
◊
◊
R
Consult factory for length
Note 6: 2 x analog channels available. Default settings are Channel 1 (voltage/current) – torque.
Channel 2 (voltage/current) – speed or power, if ordered.
Note 7: At very high speeds, for better balance the factory recommend plain or splined shafts.
Note 8: Transducers fitted for IP65 will have running speeds considerably reduced, increased drag torque and accuracy can
be affected.
Data parameters measured at +20°C
Sensor Technology Ltd reserves the right to change specification and dimensions without notice.
Содержание ORT230-C