11
DE
EN
FR
IT
ES
PT
DA
NL
SV
FI
NO
6. Troubleshooting
Fault
Possible cause
Remedy
-
System doesn’t
start
-
Display doesn’t
turn on
TorqLink supply cable fuse
defective
Check both fuses, replace if
necessary
TorqLink cables faulty
Check TorqLink cables, start-
ing from the throttle
TorqLink cable connections
faulty
Check the TorqLink cable is
properly positioned
-
Error message:
Motor undervolt-
age
-
Motor without
power supply
Main switch
Check on-position of main
switch
Fuse defective
Check fuses, replace if nec-
essary
Power cables faulty or defec-
tive.
Check installation of battery
bank and power cables
7. Disposal
Dispose of the product according to EU Directive 2012/19/EU (WEEE)
and national laws. Do not dispose of the product with household waste.
• Regularly check all cables for damage and signs of abrasion.
• Regularly check that contacts and screw connections are tight.
• Only clean the cables with a soft cloth and mild detergent that is suitable for plastics (e.g.
washing-up liquid). Do not use any chemicals or solvents for cleaning.
8. Warranty conditions
Warranty conditions and warranty certificate available at www.torqeedo.com.
9. Declaration of conformity
The EU declaration of conformity can be downloaded from www.torqeedo.com.
Torqeedo Service Partners worldwide
You can find contact details for all Torqeedo branches on the back of this manual.
Contact details for all service partners can be found under the
“Service Center” section of the partner search at www.torqeedo.com.