Toro Wireless RainSensor 53770 Скачать руководство пользователя страница 4

Detailed Installation Instructions

There are two main components of the Wireless RainSensor: the Receiver and 
the Sensor/Transmitter. The Receiver is installed adjacent to the irrigation system
controller. The Sensor/Transmitter is installed outdoors where it is exposed to 
unobstructed rainfall.

Mounting the Receiver

1.

Mount the Receiver FIRST, adjacent to the controller with either the provided stain-
less steel screws or double-sided foam tape. The connection wire cable is 20"
long, so before attaching the Receiver, make sure the wires will easily reach the
controller’s connection terminals.

Wiring the Receiver

There are two parts involved in wiring the Receiver:
Part 1: Attach the Receiver control wires.
Part 2: Attach the low-voltage power wires to supply 24 V ac to the Receiver.

Part 1 - Control Wire Connection

The Receiver control wires are used to interrupt the common wire of the valves or they
can be connected directly to the sensor input terminals of the controller (if provided).

1.

Disconnect power to the controller.

2.

Follow applicable wiring procedure 

or

or

C

.

Note:

The following diagrams are representations only and do not depict actual con-

troller layouts. Refer to the installation instructions provided with your controller for
specific wire connection information.

Locate the controller sensor terminals (generally marked “SENSOR”, “SEN” or “S”)
and directly connect the White and Brown* wires to these terminals in any order.
There may be a jumper wire or tab connecting the terminals that must be removed
and/or a sensor control or bypass switch that must be activated.

4

SENSOR

COM

PUMP/ 

MV

24 VAC

2

1

3

4

Brown

*

Common Wire From Valves

To Valves

Irrigation System Controller

White

Yellow*

*

Note:

Use the Yellow wire in place of the Brown wire if the controller requires a

Normally Open sensor. For example, the Toro ECx

TM

and GreenKeeper

®

controllers.

Controllers with sensor inputs , with or without pump start /master valve:

A

Содержание Wireless RainSensor 53770

Страница 1: ...ion methods must comply with all applicable national and local building codes If you are unsure about proper wiring practices have a qualified contrac tor perform the installation for you The Receiver...

Страница 2: ...tion will reset automatically To man ually exit the bypass mode press button again 6 Power Indicator Steady light 24 V ac power is connected Blinking light Sensor Transmitter battery power low or othe...

Страница 3: ...e controller s 24 V ac power source terminals 5 Straighten the Receiver antenna wire upward and the Sensor Transmitter antenna wire downward 6 While holding the Sensor Transmitter at close range to th...

Страница 4: ...he common wire of the valves or they can be connected directly to the sensor input terminals of the controller if provided 1 Disconnect power to the controller 2 Follow applicable wiring procedure A o...

Страница 5: ...to include the common wire from the pump start relay or master valve in this connection Attach the Brown wire to the valve common terminal Note The yellow wire is not used in this application 5 COM PU...

Страница 6: ...and 24 and Hot Post and 24 Verify correct volt age then simply attach the two Red power wires to these terminals leaving existing connections in place On controllers with no 24 V ac terminals connect...

Страница 7: ...ct with spray from the sprinklers or runoff from the roof Testing Signal Strength at the Installation Site Before installing the Sensor Transmitter test the signal strength again from the select ed in...

Страница 8: ...nd tighten to secure do not over tighten See Figure 7 The Sensor Transmitter can also be mounted on any suitable solid structure such as the side of the roof a shed or fence using the two supplied sta...

Страница 9: ...ld the Smart Bypass button until the Sensor Status Indicator begins blinking rapidly 5 7 seconds Release the Smart Bypass button and confirm the Power Indicator goes out and flashes periodically Simpl...

Страница 10: ...s small black wire and white wire loops and cut one or both loops using end cutting pliers 3 Reassemble the Sensor Transmitter and follow the procedures provided in Receiver Learn Mode on page 9 Troub...

Страница 11: ...other words passing diagonally through a wall increases its effective thickness Because every installation is differ ent the ONLY guaranteed method to verify an installation is to physically TRY IT E...

Страница 12: ...ucts During such warranty period we will repair or replace at our option any part found to be defective Return the defective part to the place of purchase Our liability is limited solely to the replac...

Отзывы: