Quick Start Installation Instructions

The following instructions are provided for the experienced installer. If you are
installing a Toro Wireless Rainsensor for the first time, use the Detailed Installation
Instructions starting on page 4.

1.

Disconnect power to the irrigation system controller.

2.

Always mount the Receiver FIRST, adjacent to the controller with either the provided
stainless steel screws or double-sided foam tape.

3.

Refer to 

Figure 3

. Attach White and Brown (or Yellow*) control wires to the con-

troller’s Sensor terminals in any order OR, to break the valve common:

a.

Disconnect valve common wire and common pump/master valve wire (if present).

b.

Attach White wire to common wire(s) with a wire connector.

c.

Attach Brown wire to common terminal on controller (Yellow wire is not used in
this connection).

4.

Connect the Red wires to the controller’s 24 V ac power source terminals.

5.

Straighten the Receiver antenna wire upward and the Sensor/Transmitter antenna
wire downward. 

6.

While holding the Sensor/Transmitter at close range to the Receiver, press and
hold the Test Spindle to test the wiring. The Power, Signal and Sensor Status indi-
cators should be ON. 

7.

Adjust the Rainfall Adjustment Cap to the desired rainfall activation amount.

8.

Mount the Sensor/Transmitter in an unobstructed location away from sprinklers.
See 

Figures 4

and 

5

Important: Reconfirm proper operation of the Wireless RainSensor at the

final mounting location.

3

Red

To 24 V ac

To 24 V ac

To Sensor Terminal or to Break Valve Common

To Sensor Terminal (Normally Closed)
or to Break Valve Common

To Sensor Terminal (Normally Open)

(For Normally Open sensor, see Detailed Instructions)

Red

White

Brown

Yellow*

Figure 3

Extend Antenna
straight down

Rain gutter (cross section view)

Do not over-tighten
thumbscrew

Press and hold
down to test

Figure 4

Extended Antenna
straight down

Stainless
Steel
Screws

Figure 5

Содержание Wireless RainSensor 53770

Страница 1: ...ion methods must comply with all applicable national and local building codes If you are unsure about proper wiring practices have a qualified contrac tor perform the installation for you The Receiver...

Страница 2: ...tion will reset automatically To man ually exit the bypass mode press button again 6 Power Indicator Steady light 24 V ac power is connected Blinking light Sensor Transmitter battery power low or othe...

Страница 3: ...e controller s 24 V ac power source terminals 5 Straighten the Receiver antenna wire upward and the Sensor Transmitter antenna wire downward 6 While holding the Sensor Transmitter at close range to th...

Страница 4: ...he common wire of the valves or they can be connected directly to the sensor input terminals of the controller if provided 1 Disconnect power to the controller 2 Follow applicable wiring procedure A o...

Страница 5: ...to include the common wire from the pump start relay or master valve in this connection Attach the Brown wire to the valve common terminal Note The yellow wire is not used in this application 5 COM PU...

Страница 6: ...and 24 and Hot Post and 24 Verify correct volt age then simply attach the two Red power wires to these terminals leaving existing connections in place On controllers with no 24 V ac terminals connect...

Страница 7: ...ct with spray from the sprinklers or runoff from the roof Testing Signal Strength at the Installation Site Before installing the Sensor Transmitter test the signal strength again from the select ed in...

Страница 8: ...nd tighten to secure do not over tighten See Figure 7 The Sensor Transmitter can also be mounted on any suitable solid structure such as the side of the roof a shed or fence using the two supplied sta...

Страница 9: ...ld the Smart Bypass button until the Sensor Status Indicator begins blinking rapidly 5 7 seconds Release the Smart Bypass button and confirm the Power Indicator goes out and flashes periodically Simpl...

Страница 10: ...s small black wire and white wire loops and cut one or both loops using end cutting pliers 3 Reassemble the Sensor Transmitter and follow the procedures provided in Receiver Learn Mode on page 9 Troub...

Страница 11: ...other words passing diagonally through a wall increases its effective thickness Because every installation is differ ent the ONLY guaranteed method to verify an installation is to physically TRY IT E...

Страница 12: ...ucts During such warranty period we will repair or replace at our option any part found to be defective Return the defective part to the place of purchase Our liability is limited solely to the replac...

Отзывы: