1
Installing the Valve-Mount
Bracket
Parts needed for this procedure:
1
Valve-mount bracket
1
Hydraulic manifold block (ordered separately)
4
Hydraulic fitting (ordered separately)
Procedure
Note:
You can find the hydraulic manifold block and
hydraulic fittings in the Ultrasonic Boom Leveling Kit.
1.
Disconnect the wiring harness from the hydraulic
manifold block (
Figure 1
1.
Hose
3.
Wiring harness
2.
Hydraulic manifold block
2.
Label all the hoses connected to the hydraulic manifold
block and disconnect them from the block (
).
3.
Loosen the 2 hydraulic connectors on the right side
and the gauge port on the left side of the hydraulic
manifold block (
Figure 2
Front side of the hydraulic manifold block
1.
Mounting bracket
4.
Gauge port
2.
Hydraulic connector
5.
Nut (5/16 inch)
3.
Bolt (5/16 x 3 inch)
4.
Remove the hydraulic manifold block from the
mounting bracket (
Note:
Retain the fasteners.
5.
Remove and retain the 2 hydraulic connectors and
gauge port from the hydraulic manifold (
6.
Remove the mounting bracket from the machine
(
Note:
Retain the fasteners.
Figure 3
1.
Bolt (5/16 x 1 inch)
2.
Nut (5/16 inch)
2