6
Connecting the Receiver Wires
CAUTION: The receiver requires continuous 24 Vac power for operation. Connecting to
110 Vac or higher will result in irreparable damage. Ensure power to the controller has been
removed prior to connecting the receiver wires.
The sensor system is designed to work with most makes and models of irrigation controllers.
• If your controller is equipped for sensor connection, follow the steps in
Wiring Procedure I
.
• If your controller is not equipped for sensor connection, use
Wiring Procedure II
on page 7.
Wiring Procedure I (sensor-ready)
Note:
Refer to your controller user’s guide for
the type of sensor required: Normally Closed
(NC) or Normally Open (NO).
1. Locate the sensor connection terminals,
usually labeled “SENSOR” or “SN.”
Remove the jumper if one is installed.
2. Attach the
White
wire to either sensor
terminal (dis and – symbols).
3. For a
normally-closed sensor,
attach the
Brown
wire to the remaining sensor terminal.
Tape back the Yellow wire. See Figure 2.
COM
PUMP/
MV
24 VAC
2
1
3
4
SENSOR
Red
Red
Red
White
Brown
Yellow
Red
White
Brown
To Valves
X
Jumper
Figure 2 - Normally-closed Sensor
RainSensorAlpha7 3/10/2005 3:31 PM Page 6