background image

FLEX800

TM

 Series Sprinklers 

FLX55-6 – 24-Position TruJectory

TM

 

 

October, 2014 

 

nozzles and a main nozzle adapter, and 10 
different color-coded inner/intermediate 

nozzles.  The main nozzle shall incorporate a 
trajectory adjustment that provides a main 
nozzle discharge angle from 7

 to 30

 in 1

 

increments.  Trajectory adjustment shall be 

capable while the sprinkler is in operation or 
not.  The sprinkler shall identify the 

trajectory adjustment setting from the top of 
the sprinkler.  Close-in watering distribution 

shall be achieved by an inner nozzle capable 
of adjusting the distribution profile to 

optimize uniformity.  The cap shall identify 
the installed main nozzle and the date of 

manufacture. 
 

The pilot valve assembly shall incorporate 
one of five electrical activation types 

(described below) to control the ON-OFF 
operation of the sprinkler.  It shall provide 

four pressure-point selections (50, 65, 80 and 
100 psi; 3,5, 4,5, 5,5 and 6,9 Bar), with a 

vandal-resistant locking feature that ensures 
the desired setting is maintained.  The 

pressure points shall be graphically illustrated 
in psi and kg/cm2.  The pilot valve assembly 

shall include a pressure-regulation feature 
that continuously monitors the operating 

pressure inside the sprinkler body, making 
the necessary adjustments to ensure the 

desired and set regulation pressure is 
maintained.  The pilot valve assembly shall 

incorporate a manual control feature that is 
accessible from the top and allows the 

sprinkler to be manually selected “ON”, 
“OFF” or placed in the “AUTO” position 

awaiting commands from the control device.  
The manual selector shall be red in color for 

enhanced visibility.  The pilot valve assembly 
shall be stamped with the manufactured 

date. 
 

The sprinkler shall incorporate an electrical 
solenoid for activation of the integrated 

control valve in one of five activation types 
as described below.   

 
 

Standard Solenoid 

 The Standard solenoid shall be suitable for 

24 VAC, 50/60 Hz service with an inrush 
current of 0.30 A @ 50/60 Hz, and holding 

current of 0.20 A @ 50/60 Hz and shall be 
capable of withstanding a voltage surge of up 

to 9k volts in the common and normal 
modes without failure. 

Spike Guard Solenoid 

 The Spike Guard solenoid shall be suitable 
for 24 VAC, 50/60 Hz service with an 

inrush current of 0.12 A @ 50/60 Hz, and 
holding current of 0.10 A @ 50/60 Hz.  and 

shall be capable of withstanding a voltage 
surge of up to 20k volts in the common and 

normal modes without failure. 
 

Nickel-Plated Spike Guard Solenoid 

  The Nickel-Plated Spike Guard solenoid 

shall be suitable for 24 VAC, 50/60 Hz 
service with inrush current of 0.12 A @ 

50/60 Hz, and holding current of 0.10 A @ 
50/60 Hz. and shall be capable of 

withstanding a voltage surge of up to 20k 
volts in the common and normal modes 

without failure.  It shall also have a nickel-
plated core to provide additional corrosion-

resistance in potable and non-potable water 
applications. 

 

DC Latching Solenoid 

  The DC latching solenoid shall be activated 
by a momentary low-voltage pulse that 

moves the plunger from the “OFF” to the 
“ON” position where it is maintained by a 

permanent magnet in the solenoid.  To 
deactivate, a second momentary low-volt 

pulse is applied to move the plunger from 
the “ON” position to the “OFF” position.  

This activation type is generally used with a 
GDC module that is remotely located. 

 
Integrated GDC Module 

  The  Integrated  GDC  Module  activation 
type incorporates the GDC module attached 

to the outside of the sprinkler body and 
includes a DC latching solenoid for 

activation of the control valve.  The DC 
latching solenoid shall be activated by the 

Integrated GDC module with a momentary 
low voltage pulse that moves the plunger 

from the “OFF” position to the “ON” 
position where it is maintained by a 

permanent magnet in the solenoid.  To 
deactivate, a second momentary low-volt 

pulse is applied to move the plunger from 
the “ON” position to the “OFF” position. 

 
 

 The internal valve assembly shall be a 
piston-type that vents to the atmosphere, 

providing valve friction loss of less than 5 
psi (0,34 Bar).  The sprinkler shall be 

designed to provide smooth valve closure in 
excess of two seconds to minimize damage 

resulting from surges and water hammer.  All 

valve seals shall be constructed of natural 
rubber.  The valve seat seal shall be 

constructed of fabric-reinforced natural 
rubber.  The electric valve assembly shall 

incorporate a 100-mesh stainless-steel screen 
for the control water, preventing entry of 

foreign materials into the pilot valve 
assembly. 

 
  The sprinkler body and cap shall be 

injection-molded from ABS – a corrosion-
proof, impact-resistant, UV-resistant, heavy-

duty, engineering-grade plastic material.  The 
cap and nozzle base shall incorporate a pull-

up feature that provides improved 
serviceability of nozzles and riser.  The 

sprinkler shall have two plastic filter screens 
– a top-serviceable coarse rock screen in the 

body inlet sized to prevent entry of larger 
foreign material from entering the body, and 

a finer screen threaded into the riser, sized to 
prevent foreign material from clogging the 

nozzle. 
 

  The sprinkler shall have a riser/body seal 
assembly that regulates flushing during pop-

up and retraction to clear any debris from 
around the riser, and a heavy-duty, stainless-

steel spring to ensure positive retraction.  
The riser is sealed by a durable, over-molded 

urethane ring on the seal retainer.  Sprinkler 
flush rate shall not exceed 5 GPM (18,9 

LPM). 
 

  The sprinkler shall be capable of identifying 
the use of effluent water via a lavender-

colored marking.  The sprinkler cap shall 
indicate model designation, nozzle number 

and manufacturing date code. 
 

The sprinkler shall be of a pop-up design 
with an overall height of 11 5/8” (295mm), a 

body flange diameter of 7

5

/

” (194mm), a 

cap diameter of 3

5

/

” (92mm) and a pop-up 

stroke of 4 

3/16

” (106mm).   The sprinkler 

shall have a 1½” (40mm) ACME female-

threaded inlet.  The sprinkler shall be capable 
of covering ___ feet radius at ___ pounds 

per square inch pressure with a discharge 
rate of ___ gallons per minute. 

   
  The sprinkler shall be developed and 

manufactured by an ISO 9001-certified 
facility.  The sprinkler shall be model 

number __________ and shall be 
manufactured by The Toro Company, 

Irrigation Division. 